LightEdge Austin 2 (AUS2)

LightEdge Austin 2 (AUS2) is an operational data center operated by LightEdge Solutions in Austin, United States. Our footprint estimate of its power is about 18 MW.

Key facts

StatusOperational
OperatorLightEdge Solutions
Facility power18 MW (range 9.1 MW to 29 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 15,099 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 7,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks4 networks
PeeringDB.
Also known asLightEdge Austin II
Address7000-B Burleson Rd
Coordinates30.20017, -97.70627
Websitelightedge.com

Power and grid

UtilityAustin Energy (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authorityERCO
Nearest gas pipelineKinder Morgan Texas Pipeline Co, intrastate pipeline, 300 m away
US Energy Information Administration pipeline map. Straight-line distance.
Grid carbon intensity379 g CO₂ per kWh (Texas, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8%
Industrial power priceUSD 0.072 per kWh (Texas, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature20.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature44.6 °C (2001 to 2025)
Cooling degree days1,858 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.81 kWh per m² per day
Wind at 50 m6.1 m/s average
Water stress todayHigh (40-80%) (Texas)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does LightEdge Austin 2 (AUS2) use?

We estimate the facility power at about 18 MW. Estimate from building footprint, low confidence.

How clean is the power for LightEdge Austin 2 (AUS2)?

The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.

Who operates LightEdge Austin 2 (AUS2)?

LightEdge Solutions.