DataBank Minneapolis (MSP3)
DataBank Minneapolis (MSP3) is an operational data center operated by DataBank in Brooklyn Park, United States. Our footprint estimate of its power is about 11 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | DataBank |
| Facility power | 11 MW (range 5.5 MW to 18 MW) Estimate from building footprint, low confidence. Footprint estimate: about 9,221 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,700 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 3 networks PeeringDB. |
| Also known as | DataBank |
| Address | 8111 Oxbow Creek N |
| Coordinates | 45.14438, -93.38591 |
| Website | databank.com/data-centers/minneapolis |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 115 kV, 3.5 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Elm Creek Substation, 345 kV, 6.2 km away |
| HV substations within 10 km | 11 |
| Utility | City Of St Paul Electric retail service territory (HIFLD, US government). |
| Balancing authority | SWPP |
| Nearest gas pipeline | Northern Natural Gas Co, interstate pipeline, 3.8 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 6.3 GW in 73 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 344 g CO₂ per kWh (Minnesota, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 25.1%, coal 23%, nuclear 21.5%, gas 20.7%, solar 5.9%. Clean power: 55.8% |
| Industrial power price | USD 0.100 per kWh (Minnesota, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.6 °C (2001 to 2025) |
| Cooling degree days | 347 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.8 kWh per m² per day |
| Wind at 50 m | 6.8 m/s average |
| Water stress today | Medium - High (20-40%) (Minnesota) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does DataBank Minneapolis (MSP3) use?
We estimate the facility power at about 11 MW. Estimate from building footprint, low confidence.
How close is DataBank Minneapolis (MSP3) to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (115 kV), about 3.5 km away. The local utility is City Of St Paul, in the SWPP balancing area.
How clean is the power for DataBank Minneapolis (MSP3)?
The grid in Minnesota emits about 344 g CO₂ per kWh (2025). Largest sources: wind 25.1%, coal 23%, nuclear 21.5%.
Who operates DataBank Minneapolis (MSP3)?
DataBank.
Data centers near Brooklyn Park
- Verus Corportation 9.1 km
- Zayo Minneapolis - 10300 6th Ave N 17.7 km
- Implex Minneapolis 18.6 km
- Verizon data center in Minneapolis 18.9 km · 6.8 MW
- Lumen Minneapolis 3 19.3 km · 2.3 MW
- US Internet - Minnetonka 19.6 km
- Atomic Data MSP250 20.4 km
- TriTech Center 20.7 km
More DataBank data centers
- Databank Orangeburg (LGA3) United States
- DataBank Salt Lake City (SLC2) United States
- DataBank Ashburn (IAD1) United States
- DataBank Dallas (DFW3) United States
- DataBank Las Vegas (LAS1) United States
- DataBank Dallas (DFW4) United States
- DataBank Seattle (SEA2) United States
- DataBank Denver (DEN2) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.