DataBank Seattle (SEA2)
DataBank Seattle (SEA2) is an operational data center operated by DataBank in Tukwila, United States. Our footprint estimate of its power is about 9.3 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | DataBank |
| Facility power | 9.3 MW (range 4.7 MW to 15 MW) Estimate from building footprint, low confidence. Footprint estimate: about 7,772 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 4 networks PeeringDB. |
| Also known as | Intergate Seattle East Building 2 |
| Address | 3311 S 120th Pl |
| Coordinates | 47.49503, -122.29057 |
| Website | databank.com/data-centers/seattle/sea2 |
Power and grid
| Nearest high-voltage substation | Creston-Nelson Substation, 230 kV, 2.2 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 6 |
| Utility | City Of Seattle (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | SCL |
| Nearest gas pipeline | Northwest Pipeline, interstate pipeline, 7.7 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 622 MW in 9 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 135 g CO₂ per kWh (Washington, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 62.8%, gas 15.7%, wind 8.3%, nuclear 7.5%, coal 3%. Clean power: 80.9% |
| Industrial power price | USD 0.074 per kWh (Washington, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 10.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38 °C (2001 to 2025) |
| Cooling degree days | 79 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.42 kWh per m² per day |
| Wind at 50 m | 3.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Washington) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does DataBank Seattle (SEA2) use?
We estimate the facility power at about 9.3 MW. Estimate from building footprint, low confidence.
How close is DataBank Seattle (SEA2) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Creston-Nelson Substation (230 kV), about 2.2 km away. The local utility is City Of Seattle, in the SCL balancing area.
How clean is the power for DataBank Seattle (SEA2)?
The grid in Washington emits about 135 g CO₂ per kWh (2025). Largest sources: hydro 62.8%, gas 15.7%, wind 8.3%.
Who operates DataBank Seattle (SEA2)?
DataBank.
Data centers near Tukwila
- Intergate Seattle East Building 3 172 m · 25 MW
- Intergate Seattle East Building 4 221 m · 12 MW
- Intergate West / Digital.forest / Fortress 305 m · 3.8 MW
- WowRack 317 m · 3.4 MW
- Centersquare Seattle (SEA1-B) 354 m · 20 MW
- EdgeConneX Seattle (EDCSEA01) 357 m
- Centersquare Seattle (SEA1-A) 378 m · 6.1 MW
- Equinix SE4 - Seattle, Kent 8.9 km
More DataBank data centers
- Databank Orangeburg (LGA3) United States
- DataBank Salt Lake City (SLC2) United States
- DataBank Ashburn (IAD1) United States
- DataBank Dallas (DFW3) United States
- DataBank Las Vegas (LAS1) United States
- DataBank Dallas (DFW4) United States
- DataBank Minneapolis (MSP3) United States
- DataBank Denver (DEN2) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.