WowRack
WowRack is an operational data center operated by Serverhosh Internet Service in Tukwila, United States. Our footprint estimate of its power is about 3.4 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Serverhosh Internet Service |
| Facility power | 3.4 MW (range 1.7 MW to 5.4 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,800 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 20 networks, 3 internet exchanges PeeringDB. |
| Also known as | ColoCrossing SEA1 · Wowrack Datacenter - Tukwila · Intergate Seattle West Building B |
| Address | 12201 Tukwila International Blvd |
| Coordinates | 47.49312, -122.29371 |
| Website | wowrack.com |
Power and grid
| Utility | City Of Seattle (municipal) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | SCL |
| Nearest gas pipeline | Northwest Pipeline, interstate pipeline, 7.8 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 135 g CO₂ per kWh (Washington, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 62.8%, gas 15.7%, wind 8.3%, nuclear 7.5%, coal 3%. Clean power: 80.9% |
| Industrial power price | USD 0.074 per kWh (Washington, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 10.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38 °C (2001 to 2025) |
| Cooling degree days | 79 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.42 kWh per m² per day |
| Wind at 50 m | 3.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Washington) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does WowRack use?
We estimate the facility power at about 3.4 MW. Estimate from building footprint, low confidence.
How clean is the power for WowRack?
The grid in Washington emits about 135 g CO₂ per kWh (2025). Largest sources: hydro 62.8%, gas 15.7%, wind 8.3%.
Who operates WowRack?
Serverhosh Internet Service.
Data centers near Tukwila
- Centersquare Seattle (SEA1-A) 107 m · 6.1 MW
- Intergate West / Digital.forest / Fortress 125 m · 3.8 MW
- Intergate Seattle East Building 3 247 m · 25 MW
- DataBank Seattle (SEA2) 317 m · 9.3 MW
- Centersquare Seattle (SEA1-B) 325 m · 20 MW
- Intergate Seattle East Building 4 364 m · 12 MW
- EdgeConneX Seattle (EDCSEA01) 632 m
- Equinix SE4 - Seattle, Kent 8.8 km
More Serverhosh Internet Service data centers
- 3W-DC01 Netherlands
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.