Lumen Minneapolis 3
Lumen Minneapolis 3 is an operational data center operated by Lumen Technologies in Minneapolis, United States. Our footprint estimate of its power is about 2.3 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Lumen Technologies |
| Facility power | 2.3 MW (range 1.2 MW to 3.7 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,928 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 980 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | North 2nd Street 715, 55401, Minneapolis |
| Coordinates | 44.98877, -93.27661 |
Power and grid
| Utility | City Of St Paul Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | SWPP |
| Nearest gas pipeline | Northern Natural Gas Co, interstate pipeline, 11.8 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 460 g CO₂ per kWh (Nebraska, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 46%, wind 29.4%, nuclear 17.4%, gas 3.2%, hydro 2.9%. Clean power: 50.7% |
| Industrial power price | USD 0.084 per kWh (Nebraska, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.6 °C (2001 to 2025) |
| Cooling degree days | 347 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.8 kWh per m² per day |
| Wind at 50 m | 6.8 m/s average |
| Water stress today | Extremely High (>80%) (Nebraska) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Lumen Minneapolis 3 use?
We estimate the facility power at about 2.3 MW. Estimate from building footprint, low confidence.
How clean is the power for Lumen Minneapolis 3?
The grid in Nebraska emits about 460 g CO₂ per kWh (2025). Largest sources: coal 46%, wind 29.4%, nuclear 17.4%.
Who operates Lumen Minneapolis 3?
Lumen Technologies.
Data centers near Minneapolis
- Verizon data center in Minneapolis 418 m · 6.8 MW
- Atomic Data MSP250 1.1 km
- TriTech Center 1.4 km
- Implex Minneapolis 1.6 km
- T5@Minneapolis 2.0 km
- Cologix MIN1 2.6 km · 15 MW
- University of Minnesota Agate 3.5 km · 0.2 MW
- Advanced Operations Center 4.1 km · 2.1 MW
More Lumen Technologies data centers
- Level(3) Weehawken United States
- Level(3) Seattle (Denny Way) United States
- Level(3) Denver United States
- Level(3) London (Braham Street) United Kingdom
- Level(3) McLean United States
- Lumen Ashburn United States
- Level(3) Sunnyvale United States
- Level(3) Dallas United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.