Advanced Operations Center
Advanced Operations Center is an operational data center operated by University of Minnesota in Minneapolis, United States. Our footprint estimate of its power is about 2.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | University of Minnesota |
| Facility power | 2.1 MW (range 1 MW to 3.3 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,717 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 900 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 44.97938, -93.22639 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 345 kV, 2.2 km away (Xcel Energy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 7 |
| Utility | City Of St Paul Electric retail service territory (HIFLD, US government). |
| Balancing authority | SWPP |
| Nearest gas pipeline | Northern Natural Gas Co, interstate pipeline, 12.7 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 4.1 GW in 68 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 460 g CO₂ per kWh (Nebraska, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 46%, wind 29.4%, nuclear 17.4%, gas 3.2%, hydro 2.9%. Clean power: 50.7% |
| Industrial power price | USD 0.084 per kWh (Nebraska, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.6 °C (2001 to 2025) |
| Cooling degree days | 345 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.8 kWh per m² per day |
| Wind at 50 m | 6.3 m/s average |
| Water stress today | Extremely High (>80%) (Nebraska) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Advanced Operations Center use?
We estimate the facility power at about 2.1 MW. Estimate from building footprint, low confidence.
How close is Advanced Operations Center to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (345 kV), about 2.2 km away. The local utility is City Of St Paul, in the SWPP balancing area.
How clean is the power for Advanced Operations Center?
The grid in Nebraska emits about 460 g CO₂ per kWh (2025). Largest sources: coal 46%, wind 29.4%, nuclear 17.4%.
Who operates Advanced Operations Center?
University of Minnesota.
Data centers near Minneapolis
- University of Minnesota Agate 906 m · 0.2 MW
- Cologix MIN1 2.4 km · 15 MW
- TriTech Center 3.1 km
- Atomic Data MSP250 3.2 km
- T5@Minneapolis 3.6 km
- Implex Minneapolis 3.9 km
- Lumen Minneapolis 3 4.1 km · 2.3 MW
- Verizon data center in Minneapolis 4.4 km · 6.8 MW
More University of Minnesota data centers
- University of Minnesota Agate United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.