Advanced Operations Center

Advanced Operations Center is an operational data center operated by University of Minnesota in Minneapolis, United States. Our footprint estimate of its power is about 2.1 MW.

Key facts

StatusOperational
OperatorUniversity of Minnesota
Facility power2.1 MW (range 1 MW to 3.3 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 1,717 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 900 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Coordinates44.97938, -93.22639

Power and grid

Nearest high-voltage substationUnnamed substation, 345 kV, 2.2 km away (Xcel Energy)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km7
UtilityCity Of St Paul
Electric retail service territory (HIFLD, US government).
Balancing authoritySWPP
Nearest gas pipelineNorthern Natural Gas Co, interstate pipeline, 12.7 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km4.1 GW in 68 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity460 g CO₂ per kWh (Nebraska, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 46%, wind 29.4%, nuclear 17.4%, gas 3.2%, hydro 2.9%. Clean power: 50.7%
Industrial power priceUSD 0.084 per kWh (Nebraska, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature7 °C
NASA POWER, average of 2001 to 2025.
Highest temperature41.6 °C (2001 to 2025)
Cooling degree days345 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.8 kWh per m² per day
Wind at 50 m6.3 m/s average
Water stress todayExtremely High (>80%) (Nebraska)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Advanced Operations Center use?

We estimate the facility power at about 2.1 MW. Estimate from building footprint, low confidence.

How close is Advanced Operations Center to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (345 kV), about 2.2 km away. The local utility is City Of St Paul, in the SWPP balancing area.

How clean is the power for Advanced Operations Center?

The grid in Nebraska emits about 460 g CO₂ per kWh (2025). Largest sources: coal 46%, wind 29.4%, nuclear 17.4%.

Who operates Advanced Operations Center?

University of Minnesota.