Cologix MIN1

Cologix MIN1 is an operational data center operated by Cologix in Minneapolis, United States. Our footprint estimate of its power is about 15 MW.

Key facts

StatusOperational
OperatorCologix
Facility power15 MW (range 7.3 MW to 23 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 12,196 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 6,400 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks83 networks, 6 internet exchanges
PeeringDB.
Also known asCologix MIN2 · Cologix MIN3 · Cologix MIN4 · mindSHIFT Minneapolis · DataBank Minneapolis (MSP4) · Aureon Minneapolis
Address511 11th Ave S Ste 100
Coordinates44.97141, -93.25458
Websitecologix.com

Power and grid

Nearest high-voltage substation5th Street Substation, 115 kV, 1.6 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationTerminal Substation, 345 kV, 4.5 km away
HV substations within 10 km9
UtilityCity Of St Paul
Electric retail service territory (HIFLD, US government).
Balancing authoritySWPP
Nearest gas pipelineNorthern Natural Gas Co, interstate pipeline, 13.6 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km4.1 GW in 69 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity460 g CO₂ per kWh (Nebraska, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 46%, wind 29.4%, nuclear 17.4%, gas 3.2%, hydro 2.9%. Clean power: 50.7%
Industrial power priceUSD 0.084 per kWh (Nebraska, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature7 °C
NASA POWER, average of 2001 to 2025.
Highest temperature41.6 °C (2001 to 2025)
Cooling degree days347 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.8 kWh per m² per day
Wind at 50 m6.8 m/s average
Water stress todayExtremely High (>80%) (Nebraska)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Cologix MIN1 use?

We estimate the facility power at about 15 MW. Estimate from building footprint, low confidence.

How close is Cologix MIN1 to the power grid?

The nearest high-voltage substation in OpenStreetMap is 5th Street Substation (115 kV), about 1.6 km away. The local utility is City Of St Paul, in the SWPP balancing area.

How clean is the power for Cologix MIN1?

The grid in Nebraska emits about 460 g CO₂ per kWh (2025). Largest sources: coal 46%, wind 29.4%, nuclear 17.4%.

Who operates Cologix MIN1?

Cologix.