DC Blox data center in East Highland Park is an operational data center operated by DC Blox in East Highland Park, United States. Our footprint estimate of its power is about 6.3 MW.

Key facts

StatusOperational
OperatorDC Blox
Facility power6.3 MW (range 2.5 MW to 16 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 52,725 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 2,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Coordinates37.60459, -77.42269

Power and grid

Nearest high-voltage substationUnnamed substation, 115 kV, 3.5 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationLakeside Substation, 230 kV, 3.6 km away
HV substations within 10 km11
UtilityVirginia Electric & Power Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineVirginia Natural Gas Co, intrastate pipeline, 0 m away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km3.3 GW in 26 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity357 g CO₂ per kWh (Virginia, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39%
Industrial power priceUSD 0.100 per kWh (Virginia, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature14.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature41.4 °C (2001 to 2025)
Cooling degree days924 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.27 kWh per m² per day
Wind at 50 m4.4 m/s average
Water stress todayMedium - High (20-40%) (Virginia)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does DC Blox data center in East Highland Park use?

We estimate the facility power at about 6.3 MW. Estimate from building footprint, low confidence.

How close is DC Blox data center in East Highland Park to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (115 kV), about 3.5 km away. The local utility is Virginia Electric & Power Co, in the PJM balancing area.

How clean is the power for DC Blox data center in East Highland Park?

The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.

Who operates DC Blox data center in East Highland Park?

DC Blox.

Data centers near East Highland Park

More DC Blox data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.