Digital Realty FRA27

Digital Realty FRA27 is an operational data center operated by Digital Realty in Frankfurt am Main, Germany. Our footprint estimate of its power is about 4 MW.

Key facts

StatusOperational
OperatorDigital Realty
Facility power4 MW (range 2 MW to 6.4 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 3,344 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 1,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressHugo-Junkers-Straße 7a, 60386, Frankfurt am Main
Coordinates50.12419, 8.74888

Power and grid

Nearest high-voltage substationUnnamed substation, 110 kV, 800 m away (Netzdienste Rhein-Main)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationUmspannwerk Frankfurt Nord, 220 kV, 4 km away
HV substations within 10 km33
Power plants within 50 km3.0 GW in 44 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity334 g CO₂ per kWh (Germany, 2025)
Average of all power made in the area. Ember.
Grid power mixwind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5%
Industrial power priceEUR 0.146 per kWh (Germany, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.8 °C (2001 to 2025)
Cooling degree days233 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.98 kWh per m² per day
Wind at 50 m5.7 m/s average
Water stress todayMedium - High (20-40%) (Germany)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Digital Realty FRA27 use?

We estimate the facility power at about 4 MW. Estimate from building footprint, low confidence.

How close is Digital Realty FRA27 to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (110 kV), about 800 m away.

How clean is the power for Digital Realty FRA27?

The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.

Who operates Digital Realty FRA27?

Digital Realty.