Iron Mountain FRA-1
Iron Mountain FRA-1 is an operational data center operated by Iron Mountain in Frankfurt am Main, Germany. Our footprint estimate of its power is about 38 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Iron Mountain |
| Facility power | 38 MW (range 19 MW to 61 MW) Estimate from building footprint, low confidence. Footprint estimate: about 7,999 m² building outline x 4 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 16,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Borsigallee 1, 60388, Frankfurt am Main |
| Coordinates | 50.13368, 8.73988 |
| Website | ironmountain.com/data-centers/locations/frankfurt-data-center |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 110 kV, 100 m away (Netzdienste Rhein-Main) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Frankfurt Nord, 220 kV, 2.9 km away |
| HV substations within 10 km | 35 |
| Power plants within 50 km | 3.0 GW in 43 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Iron Mountain FRA-1 use?
We estimate the facility power at about 38 MW. Estimate from building footprint, low confidence.
How close is Iron Mountain FRA-1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (110 kV), about 100 m away.
How clean is the power for Iron Mountain FRA-1?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Iron Mountain FRA-1?
Iron Mountain.
Data centers near Frankfurt am Main
- Mainova WebHouse 269 m · 5.9 MW
- Equinix FR11 531 m · 9.1 MW
- firstcolo - FRA4 737 m
- Equinix FR2 - Frankfurt, North 923 m
- Equinix Germany GmbH 973 m · 12 MW
- Digital Realty FRA27 1.2 km · 4 MW
- Digital Realty FRA18 -22 1.2 km · 60 MW
- iNTERWERK Rechenzentrum 1.3 km · 4 MW
More Iron Mountain data centers
- Iron Mountain Data Center - New Jersey (NJE-1) United States
- Iron Mountain data center in Sandston United States
- Iron Mountain Data Center - Manassas (VA-1) United States
- Iron Mountain VA-3 United States
- Iron Mountain Data Center - Manassas (VA-2) United States
- Iron Mountain VA-7 United States
- Iron Mountain Data Center - London (LON-1) United Kingdom
- Iron Mountain Australia
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.