Equinix FR2 - Frankfurt, North
Equinix FR2 - Frankfurt, North is an operational data center operated by Equinix in Frankfurt, Germany. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Networks | 72 networks, 6 internet exchanges PeeringDB. |
| Address | Kruppstrasse 121-127 |
| Coordinates | 50.14189, 8.74176 |
| Website | equinix.com/locations/germany-colocation/frankfurt-data-centers/fr2 |
Power and grid
| Nearest high-voltage substation | Umspannwerk Kruppstraße, 110 kV, 200 m away (Netzdienste Rhein-Main) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Frankfurt Nord, 220 kV, 2 km away |
| HV substations within 10 km | 30 |
| Power plants within 50 km | 3.0 GW in 44 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Equinix FR2 - Frankfurt, North to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Kruppstraße (110 kV), about 200 m away.
How clean is the power for Equinix FR2 - Frankfurt, North?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Equinix FR2 - Frankfurt, North?
Equinix.
Data centers near Frankfurt
- Equinix Germany GmbH 178 m · 12 MW
- firstcolo - FRA4 253 m
- Equinix FR11 396 m · 9.1 MW
- Mainova WebHouse 700 m · 5.9 MW
- Iron Mountain FRA-1 923 m · 38 MW
- Digital Realty FRA18 -22 2.0 km · 60 MW
- Digital Realty FRA27 2.0 km · 4 MW
- iNTERWERK Rechenzentrum 2.2 km · 4 MW
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.