Iron Mountain Data Center - Manassas (VA-2)
Iron Mountain Data Center - Manassas (VA-2) is an operational data center operated by Iron Mountain in Manassas, United States. Our footprint estimate of its power is about 34 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Iron Mountain |
| Facility power | 34 MW (range 17 MW to 54 MW) Estimate from building footprint, low confidence. Footprint estimate: about 28,166 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 15,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 3 networks PeeringDB. |
| Also known as | Iron Mountain VA-6 |
| Address | 11660 Hayden Road |
| Coordinates | 38.77023, -77.53902 |
| Website | ironmountain.com/digital-transformation/data-centers/locations/virginia-data-center |
Power and grid
| Nearest high-voltage substation | Liberty Substation, 230 kV, 600 m away (Dominion Energy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 48 |
| Utility | Northern Virginia Elec Coop (cooperative) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Transcontinental Gas PL, interstate pipeline, 200 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 3.4 GW in 30 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 357 g CO₂ per kWh (Virginia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39% |
| Industrial power price | USD 0.100 per kWh (Virginia, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.7 °C (2001 to 2025) |
| Cooling degree days | 729 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.98 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | Medium - High (20-40%) (Virginia) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Iron Mountain Data Center - Manassas (VA-2) use?
We estimate the facility power at about 34 MW. Estimate from building footprint, low confidence.
How close is Iron Mountain Data Center - Manassas (VA-2) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Liberty Substation (230 kV), about 600 m away. The local utility is Northern Virginia Elec Coop, in the PJM balancing area.
How clean is the power for Iron Mountain Data Center - Manassas (VA-2)?
The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.
Who operates Iron Mountain Data Center - Manassas (VA-2)?
Iron Mountain.
Data centers near Manassas
- Iron Mountain VA-5 364 m · 20 MW
- Iron Mountain VA-7 556 m · 33 MW
- Data center in Linton Hall 776 m · 5.3 MW
- Iron Mountain VA-3 795 m · 37 MW
- Amazon IAD-95 915 m · 65 MW
- Data center in Linton Hall 984 m · 17 MW
- Amazon IAD-85 1.1 km · 65 MW
- Iron Mountain Data Center - Manassas (VA-1) 1.1 km · 40 MW
More Iron Mountain data centers
- Iron Mountain Data Center - New Jersey (NJE-1) United States
- Iron Mountain data center in Sandston United States
- Iron Mountain Data Center - Manassas (VA-1) United States
- Iron Mountain FRA-1 Germany
- Iron Mountain VA-3 United States
- Iron Mountain VA-7 United States
- Iron Mountain Data Center - London (LON-1) United Kingdom
- Iron Mountain Australia
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.