Digital Realty FRA33
Digital Realty FRA33 is an operational data center in Hattersheim, Germany. Our footprint estimate of its power is about 31 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 31 MW (range 15 MW to 49 MW) Estimate from building footprint, low confidence. Footprint estimate: about 25,473 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 13,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 50.05472, 8.45768 |
Power and grid
| Nearest high-voltage substation | Umspannwerk Marxheim, 110 kV, 1.7 km away (Süwag Energie) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Kabeleinführung 380 kV, 380 kV, 4.5 km away |
| HV substations within 10 km | 22 |
| Power plants within 50 km | 3.3 GW in 42 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Digital Realty FRA33 use?
We estimate the facility power at about 31 MW. Estimate from building footprint, low confidence.
How close is Digital Realty FRA33 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Marxheim (110 kV), about 1.7 km away.
How clean is the power for Digital Realty FRA33?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Data centers near Hattersheim
- Data center in Hattersheim 2.1 km · 28 MW
- NTT Frankfurt 4 Data Center (FRA4) 2.2 km · 11 MW
- Digital Realty data center in Hattersheim 2.2 km · 28 MW
- Digital Realty 2.4 km · 7.4 MW
- Vantage Data Center FRA31 4.3 km · 12 MW
- Vantage Data Center FRA21 4.6 km · 71 MW
- Keppel Data Centres | Kelsterbach Data Centre 4.8 km
- Titan Networks Frankfurt 6.1 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.