Vantage Data Center FRA21

Vantage Data Center FRA21 is an operational data center operated by Vantage Data Centers in Raunheim, Germany. Our footprint estimate of its power is about 71 MW.

Key facts

StatusOperational
OperatorVantage Data Centers
Facility power71 MW (range 36 MW to 114 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 14,837 m² building outline x 4 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 30,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asVantage Data Center FRA22
Coordinates50.01320, 8.46187
Websitevantage-dc.com/data-center-locations/emea/frankfurt-ii-germany

Power and grid

Nearest high-voltage substationUmspannwerk Waldweg, 110 kV, 2.4 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationKabeleinführung 380 kV, 380 kV, 5.8 km away
HV substations within 10 km21
Power plants within 50 km3.3 GW in 42 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity334 g CO₂ per kWh (Germany, 2025)
Average of all power made in the area. Ember.
Grid power mixwind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5%
Industrial power priceEUR 0.146 per kWh (Germany, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.8 °C (2001 to 2025)
Cooling degree days233 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.98 kWh per m² per day
Wind at 50 m5.7 m/s average
Water stress todayMedium - High (20-40%) (Germany)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Vantage Data Center FRA21 use?

We estimate the facility power at about 71 MW. Estimate from building footprint, low confidence.

How close is Vantage Data Center FRA21 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Umspannwerk Waldweg (110 kV), about 2.4 km away.

How clean is the power for Vantage Data Center FRA21?

The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.

Who operates Vantage Data Center FRA21?

Vantage Data Centers.