Vantage Data Center FRA21
Vantage Data Center FRA21 is an operational data center operated by Vantage Data Centers in Raunheim, Germany. Our footprint estimate of its power is about 71 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Vantage Data Centers |
| Facility power | 71 MW (range 36 MW to 114 MW) Estimate from building footprint, low confidence. Footprint estimate: about 14,837 m² building outline x 4 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 30,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | Vantage Data Center FRA22 |
| Coordinates | 50.01320, 8.46187 |
| Website | vantage-dc.com/data-center-locations/emea/frankfurt-ii-germany |
Power and grid
| Nearest high-voltage substation | Umspannwerk Waldweg, 110 kV, 2.4 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Kabeleinführung 380 kV, 380 kV, 5.8 km away |
| HV substations within 10 km | 21 |
| Power plants within 50 km | 3.3 GW in 42 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Vantage Data Center FRA21 use?
We estimate the facility power at about 71 MW. Estimate from building footprint, low confidence.
How close is Vantage Data Center FRA21 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Waldweg (110 kV), about 2.4 km away.
How clean is the power for Vantage Data Center FRA21?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Vantage Data Center FRA21?
Vantage Data Centers.
Data centers near Raunheim
- Vantage Data Center FRA31 530 m · 12 MW
- Data center in Königstädten 4.2 km · 8.4 MW
- NTT Frankfurt 3 Data Center (FRA3) 4.4 km · 8.4 MW
- Entserv 4.4 km · 1.3 MW
- Digital Realty FRA33 4.6 km · 31 MW
- Data center in Hattersheim 5.6 km · 28 MW
- Digital Realty data center in Hattersheim 5.7 km · 28 MW
- NTT Frankfurt 4 Data Center (FRA4) 5.9 km · 11 MW
More Vantage Data Centers data centers
- Vantage TX1 United States
- Vantage VA2 United States
- Vantage VA3 United States
- Vantage VA13 United States
- Vantage San Antonio II United States
- Vantage Data Centers - CWL1 United Kingdom
- Vantage Data Centers AZ1 Campus United States
- Vantage Santa Clara CA2 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.