Entserv

Entserv is an operational data center in Rüsselsheim am Main, Germany. Our footprint estimate of its power is about 1.3 MW.

Key facts

StatusOperational
Facility power1.3 MW (range 0.5 MW to 3.3 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 10,933 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 560 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asDXC Technology Company
AddressEisenstraße 43, 65428, Rüsselsheim am Main
Coordinates49.97834, 8.43232

Power and grid

Nearest high-voltage substationUmspannwerk Waldweg, 110 kV, 2.2 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationUmspannstation Bischofsheim, 380 kV, 3.1 km away
HV substations within 10 km14
Power plants within 50 km3.3 GW in 42 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity334 g CO₂ per kWh (Germany, 2025)
Average of all power made in the area. Ember.
Grid power mixwind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5%
Industrial power priceEUR 0.146 per kWh (Germany, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.8 °C (2001 to 2025)
Cooling degree days233 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.98 kWh per m² per day
Wind at 50 m5.7 m/s average
Water stress todayMedium - High (20-40%) (Germany)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Entserv use?

We estimate the facility power at about 1.3 MW. Estimate from building footprint, low confidence.

How close is Entserv to the power grid?

The nearest high-voltage substation in OpenStreetMap is Umspannwerk Waldweg (110 kV), about 2.2 km away.

How clean is the power for Entserv?

The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.

Data centers near Rüsselsheim am Main

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.