Digital Realty data center in Hattersheim
Digital Realty data center in Hattersheim is an operational data center operated by Digital Realty in Hattersheim, Germany. Our footprint estimate of its power is about 28 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Digital Realty |
| Facility power | 28 MW (range 14 MW to 45 MW) Estimate from building footprint, low confidence. Footprint estimate: about 5,874 m² building outline x 4 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 12,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | Digital Realty FRA33 |
| Coordinates | 50.06218, 8.48686 |
Power and grid
| Nearest high-voltage substation | Umspannwerk Hattersheim, 110 kV, 1.8 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Kabeleinführung 380 kV, 380 kV, 2.8 km away |
| HV substations within 10 km | 23 |
| Power plants within 50 km | 3.3 GW in 42 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Digital Realty data center in Hattersheim use?
We estimate the facility power at about 28 MW. Estimate from building footprint, low confidence.
How close is Digital Realty data center in Hattersheim to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Hattersheim (110 kV), about 1.8 km away.
How clean is the power for Digital Realty data center in Hattersheim?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Digital Realty data center in Hattersheim?
Digital Realty.
Data centers near Hattersheim
- Data center in Hattersheim 155 m · 28 MW
- NTT Frankfurt 4 Data Center (FRA4) 216 m · 11 MW
- Digital Realty 255 m · 7.4 MW
- Digital Realty FRA33 2.2 km · 31 MW
- Keppel Data Centres | Kelsterbach Data Centre 3.0 km
- Universitaet Frankfurt Goethe-NHR 5.2 km · 0.3 MW
- Vantage Data Center FRA31 5.5 km · 12 MW
- Vantage Data Center FRA21 5.7 km · 71 MW
More Digital Realty data centers
- Digital Realty CH1 - Chicago United States
- Digital Realty IAD39 United States
- Digital Realty IAD51 United States
- Digital Realty IAD44 United States
- Digital Realty IAD41 United States
- Digital Realty Singapore SIN11 Singapore
- Digital Realty Toronto YYZ11 Canada
- Digital Realty IAD43 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.