Vantage Santa Clara CA2

Vantage Santa Clara CA2 is an operational data center operated by Vantage Data Centers in Santa Clara, United States. Our footprint estimate of its power is about 16 MW.

Key facts

StatusOperational
OperatorVantage Data Centers
Facility power16 MW (range 8.2 MW to 26 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 13,689 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 6,800 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressMathew Street 737, 95051, Santa Clara
Coordinates37.36400, -121.94689
Websitevantage-dc.com/data-center-locations/north-america/santa-clara-ii-california

Power and grid

UtilityCity Of Santa Clara (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authorityCISO
Nearest gas pipelineCalifornia Gas Transmission Co, intrastate pipeline, 3.2 km away
US Energy Information Administration pipeline map. Straight-line distance.
Grid carbon intensity189 g CO₂ per kWh (California, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7%
Industrial power priceUSD 0.241 per kWh (California, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature14 °C
NASA POWER, average of 2001 to 2025.
Highest temperature45.3 °C (2001 to 2025)
Cooling degree days370 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy5.32 kWh per m² per day
Wind at 50 m4.6 m/s average
Water stress todayExtremely High (>80%) (California)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Vantage Santa Clara CA2 use?

We estimate the facility power at about 16 MW. Estimate from building footprint, low confidence.

How clean is the power for Vantage Santa Clara CA2?

The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.

Who operates Vantage Santa Clara CA2?

Vantage Data Centers.