STACK SVY02
STACK SVY02 is an operational data center operated by STACK Infrastructure in Santa Clara, United States. Our footprint estimate of its power is about 12 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | STACK Infrastructure |
| Facility power | 12 MW (range 6 MW to 19 MW) Estimate from building footprint, low confidence. Footprint estimate: about 10,010 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 5,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 37.36193, -121.95373 |
| Website | stackinfra.com/locations/americas/silicon-valley/svy02 |
Power and grid
| Utility | City Of Santa Clara (municipal) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | CISO |
| Nearest gas pipeline | California Gas Transmission Co, intrastate pipeline, 3.2 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 14 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 45.3 °C (2001 to 2025) |
| Cooling degree days | 370 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.32 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does STACK SVY02 use?
We estimate the facility power at about 12 MW. Estimate from building footprint, low confidence.
How clean is the power for STACK SVY02?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates STACK SVY02?
STACK Infrastructure.
Data centers near Santa Clara
- EdgeConneX Santa Clara (EDCSVC01/EDCSVC02) 528 m · 5.4 MW
- Microsoft 643 m · 26 MW
- Vantage Santa Clara CA2 647 m · 16 MW
- NTT Silicon Valley data center campus 803 m · 1.4 MW
- Bay Area Internet 807 m · 18 MW
- Digital Realty SJC (2220 De La Cruz Blvd) 880 m · 60 MW
- Prime Santa Clara 963 m
- Digital Realty SJC (2805 Lafayette) 1.3 km · 16 MW
More STACK Infrastructure data centers
- STACK Infrastructure NVA02 United States
- STACK NVA05B United States
- STACK NVA06 United States
- STACK NVA02E United States
- STACK NVA02x United States
- STACK NVA05A United States
- Stack Infrastructure Portland PORO2 United States
- STACK NVA01A United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.