Stack Infrastructure Portland PORO2

Stack Infrastructure Portland PORO2 is an operational data center operated by STACK Infrastructure in Hillsboro, United States. Our footprint estimate of its power is about 28 MW.

Key facts

StatusOperational
OperatorSTACK Infrastructure
Facility power28 MW (range 14 MW to 44 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 22,924 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 12,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks9 networks, 2 internet exchanges
PeeringDB.
Also known asOpus Interactive Hillsboro (HIO01) · Stack Infrastructure - POR02
Address8135 NE Evergreen Pkwy
Coordinates45.54740, -122.89791
Websitestackinfra.com/markets/portland

Power and grid

Nearest high-voltage substationKeeler Substation, 500 kV, 300 m away (Bonneville Power Administration)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km12
UtilityPortland General Electric Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPGE
Nearest gas pipelineNorthwest Pipeline, interstate pipeline, 12.8 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km832 MW in 39 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity200 g CO₂ per kWh (Oregon, 2025)
Average of all power made in the area. Ember.
Grid power mixhydro 44.6%, gas 33.9%, wind 14.5%, solar 5.2%, bioenergy 1.6%. Clean power: 66.2%
Industrial power priceUSD 0.087 per kWh (Oregon, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature10 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.3 °C (2001 to 2025)
Cooling degree days79 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.67 kWh per m² per day
Wind at 50 m4 m/s average
Water stress todayLow - Medium (10-20%) (Oregon)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Stack Infrastructure Portland PORO2 use?

We estimate the facility power at about 28 MW. Estimate from building footprint, low confidence.

How close is Stack Infrastructure Portland PORO2 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Keeler Substation (500 kV), about 300 m away. The local utility is Portland General Electric Co, in the PGE balancing area.

How clean is the power for Stack Infrastructure Portland PORO2?

The grid in Oregon emits about 200 g CO₂ per kWh (2025). Largest sources: hydro 44.6%, gas 33.9%, wind 14.5%.