Digital Realty Stockholm STO1-6
Digital Realty Stockholm STO1-6 is an operational data center operated by Digital Realty in Stockholm, Sweden. Our footprint estimate of its power is about 54 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Digital Realty |
| Facility power | 54 MW (range 27 MW to 87 MW) Estimate from building footprint, low confidence. Footprint estimate: about 45,300 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 23,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 131 networks, 13 internet exchanges PeeringDB. |
| Also known as | Digital Realty Stockholm STO1-STO5 |
| Address | Esbogatan 11, Kista |
| Coordinates | 59.42223, 17.91670 |
| Website | interxion.com |
Power and grid
| Nearest high-voltage substation | Häggvik, 132 kV, 2.9 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Järva, 220 kV, 6.2 km away |
| HV substations within 10 km | 7 |
| Power plants within 50 km | 4 MW in 1 plant
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 36 g CO₂ per kWh (Sweden, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 40%, nuclear 27.4%, wind 22.8%, bioenergy 5.9%, solar 2.6%. Clean power: 98.7% |
| Industrial power price | EUR 0.096 per kWh (Sweden, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 6.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 31.8 °C (2001 to 2025) |
| Cooling degree days | 59 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.79 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Medium - High (20-40%) (Stockholm) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Digital Realty Stockholm STO1-6 use?
We estimate the facility power at about 54 MW. Estimate from building footprint, low confidence.
How close is Digital Realty Stockholm STO1-6 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Häggvik (132 kV), about 2.9 km away.
How clean is the power for Digital Realty Stockholm STO1-6?
The grid in Sweden emits about 36 g CO₂ per kWh (2025). Largest sources: hydro 40%, nuclear 27.4%, wind 22.8%.
Who operates Digital Realty Stockholm STO1-6?
Digital Realty.
Data centers near Stockholm
- atNorth SWE01 827 m
- Obenet Kista Gate 2.3 km
- STOKAB KN3, Kista 2.4 km
- Bahnhof data center in Sollentuna 2.5 km · 0.6 MW
- MCI Stockholm (Kista) 2.7 km
- Bahnhof Gullan 3.4 km
- Conapto Stockholm Nord (Sollentuna) 3.7 km
- Equinix SK3 - Stockholm, Spånga 4.2 km
More Digital Realty data centers
- Digital Realty CH1 - Chicago United States
- Digital Realty IAD39 United States
- Digital Realty IAD51 United States
- Digital Realty IAD44 United States
- Digital Realty IAD41 United States
- Digital Realty Singapore SIN11 Singapore
- Digital Realty Toronto YYZ11 Canada
- Digital Realty IAD43 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.