Equinix SK2 - Stockholm, Sköndal
Equinix SK2 - Stockholm, Sköndal is an operational data center operated by Equinix in Stockholm, Sweden. Our footprint estimate of its power is about 12 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 12 MW (range 6.1 MW to 19 MW) Estimate from building footprint, low confidence. Footprint estimate: about 10,111 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 5,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 36 networks, 10 internet exchanges PeeringDB. |
| Also known as | Equinix Stockholm SK2 |
| Address | Kvastvägen 25-29 |
| Coordinates | 59.26352, 18.10566 |
| Website | equinix.com/locations/europe-colocation/sweden-colocation/stockholm-data-centers/sk2 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 220 kV, 2.3 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 9 |
| Grid carbon intensity | 36 g CO₂ per kWh (Sweden, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 40%, nuclear 27.4%, wind 22.8%, bioenergy 5.9%, solar 2.6%. Clean power: 98.7% |
| Industrial power price | EUR 0.096 per kWh (Sweden, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 6.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 31.8 °C (2001 to 2025) |
| Cooling degree days | 59 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.79 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Medium - High (20-40%) (Stockholm) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix SK2 - Stockholm, Sköndal use?
We estimate the facility power at about 12 MW. Estimate from building footprint, low confidence.
How close is Equinix SK2 - Stockholm, Sköndal to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (220 kV), about 2.3 km away.
How clean is the power for Equinix SK2 - Stockholm, Sköndal?
The grid in Sweden emits about 36 g CO₂ per kWh (2025). Largest sources: hydro 40%, nuclear 27.4%, wind 22.8%.
Who operates Equinix SK2 - Stockholm, Sköndal?
Equinix.
Data centers near Stockholm
- STOKAB KN6, Hammarby 4.0 km
- Obenet Riverlake 5.5 km
- Bahnhof Pionen 5.6 km
- Glesys Stockholm 1 5.8 km
- STOKAB KN5, Södermalm 6.7 km
- City Hosting 8.0 km
- STOKAB KN7, Östermalm 8.5 km
- Bahnhof Thule 8.5 km
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.