Equinix SV1/SV5/SV10 - Silicon Valley, San Jose
Equinix SV1/SV5/SV10 - Silicon Valley, San Jose is an operational data center operated by Equinix in San Jose, United States. Our footprint estimate of its power is about 36 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 36 MW (range 18 MW to 57 MW) Estimate from building footprint, low confidence. Footprint estimate: about 29,668 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 15,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 284 networks, 8 internet exchanges PeeringDB. |
| Also known as | Equinix SV5 · Equinix SV10 · Equinix SV11 · Equinix SV1 |
| Address | 11 Great Oaks Blvd |
| Coordinates | 37.24177, -121.78297 |
| Website | equinix.com/locations/americas-colocation/united-states-colocation/silicon-valley-data-centers |
Power and grid
| Nearest high-voltage substation | Humminbird Substation, 115 kV, 400 m away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Metcalf Substation, 500 kV, 3.9 km away |
| HV substations within 10 km | 8 |
| Utility | Pacific Gas & Electric Co. (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | CISO |
| Nearest gas pipeline | California Gas Transmission Co, intrastate pipeline, 2.1 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 3.7 GW in 23 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 13.7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.7 °C (2001 to 2025) |
| Cooling degree days | 167 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.32 kWh per m² per day |
| Wind at 50 m | 4 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix SV1/SV5/SV10 - Silicon Valley, San Jose use?
We estimate the facility power at about 36 MW. Estimate from building footprint, low confidence.
How close is Equinix SV1/SV5/SV10 - Silicon Valley, San Jose to the power grid?
The nearest high-voltage substation in OpenStreetMap is Humminbird Substation (115 kV), about 400 m away. The local utility is Pacific Gas & Electric Co., in the CISO balancing area.
How clean is the power for Equinix SV1/SV5/SV10 - Silicon Valley, San Jose?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates Equinix SV1/SV5/SV10 - Silicon Valley, San Jose?
Equinix.
Data centers near San Jose
- DataPipe Silicon Valley One 13.8 km · 32 MW
- KDWEB San Jose 13.9 km
- 190 Park Center Plaza San Jose 14.0 km
- CoreSite - San Jose (SV1) 14.1 km
- SVTIX San Jose 14.9 km
- Evocative San Jose (SV7) 15.6 km
- Forescout Technologies, Inc. 17.1 km
- Equinix SV3 - Silicon Valley, San Jose 18.8 km · 20 MW
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources