Eurofiber Datacenter Rotterdam 1
Eurofiber Datacenter Rotterdam 1 is an operational data center operated by Eurofiber in Alblasserdam, Netherlands. Our footprint estimate of its power is about 1.9 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Eurofiber |
| Facility power | 1.9 MW (range 1 MW to 3.1 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,600 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 810 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 27 networks, 3 internet exchanges PeeringDB. |
| Also known as | Eurofiber data center Rotterdam 1 |
| Address | van Coulsterweg 6 |
| Opened | 2010 |
| Coordinates | 51.84591, 4.67915 |
| Website | eurofibercloudinfra.com |
Power and grid
| Nearest high-voltage substation | 150 kV Alblasserdam, 150 kV, 400 m away (TenneT) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | 380 kV Crayestein, 380 kV, 5.9 km away |
| HV substations within 10 km | 12 |
| Power plants within 50 km | 7.3 GW in 90 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 254 g CO₂ per kWh (Netherlands, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 34.9%, wind 25%, solar 21.1%, coal 7.1%, bioenergy 5.1%. Clean power: 54.2% |
| Industrial power price | EUR 0.139 per kWh (Netherlands, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.5 °C (2001 to 2025) |
| Cooling degree days | 62 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.97 kWh per m² per day |
| Wind at 50 m | 7.4 m/s average |
| Water stress today | Low - Medium (10-20%) (Netherlands) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Eurofiber Datacenter Rotterdam 1 use?
We estimate the facility power at about 1.9 MW. Estimate from building footprint, low confidence.
How close is Eurofiber Datacenter Rotterdam 1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is 150 kV Alblasserdam (150 kV), about 400 m away.
How clean is the power for Eurofiber Datacenter Rotterdam 1?
The grid in Netherlands emits about 254 g CO₂ per kWh (2025). Largest sources: gas 34.9%, wind 25%, solar 21.1%.
Who operates Eurofiber Datacenter Rotterdam 1?
Eurofiber.
Data centers near Alblasserdam
- ILA/Regeneration site PoP-Krimpen aan den IJssel 8.0 km
- Databarn Rivium 11.6 km
- GrafiX Internet B.V. - Capelle 13.6 km
- InterBox Internet 14.5 km
- NorthC Rotterdam Waalhaven 16.1 km · 1.2 MW
- Luna.nl Rotterdam Puntegale 16.2 km
- Intermax Schouwburgplein Rotterdam 16.3 km
- Smartdc Rotterdam 19.0 km
More Eurofiber data centers
- Eurofiber Datacenter Utrecht 1 Netherlands
- Eurofiber Datacenter NL Zuid-West 2 Netherlands
- Eurofiber Datacenter Groningen 1 Netherlands
- Eurofiber Datacenter Amsterdam 1 Netherlands
- Eurofiber Datacenter Arnhem 1 Netherlands
- Eurofiber Datacenter NL Zuid-West 1 Netherlands
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.