Eurofiber Datacenter Utrecht 1

Eurofiber Datacenter Utrecht 1 is an operational data center operated by Eurofiber in Groenekan, Netherlands. Our footprint estimate of its power is about 3.4 MW.

Key facts

StatusOperational
OperatorEurofiber
Facility power3.4 MW (range 1.7 MW to 5.4 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 2,838 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 1,500 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks23 networks, 2 internet exchanges
PeeringDB.
Also known asEurofiber data center Utrecht 1
AddressKoningin Wilhelminaweg 471
Opened1982
Coordinates52.12276, 5.14309
Websiteeurofibercloudinfra.com

Power and grid

Nearest high-voltage substationUnnamed substation, 150 kV, 2.8 km away (TenneT)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substation380 kV Breukelen Kortrijk, 380 kV, 11.4 km away
HV substations within 10 km7
Power plants within 50 km3.4 GW in 77 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity254 g CO₂ per kWh (Netherlands, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 34.9%, wind 25%, solar 21.1%, coal 7.1%, bioenergy 5.1%. Clean power: 54.2%
Industrial power priceEUR 0.139 per kWh (Netherlands, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature35.8 °C (2001 to 2025)
Cooling degree days76 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.97 kWh per m² per day
Wind at 50 m7 m/s average
Water stress todayLow (<10%) (Utrecht)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low (<10%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Eurofiber Datacenter Utrecht 1 use?

We estimate the facility power at about 3.4 MW. Estimate from building footprint, low confidence.

How close is Eurofiber Datacenter Utrecht 1 to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (150 kV), about 2.8 km away.

How clean is the power for Eurofiber Datacenter Utrecht 1?

The grid in Netherlands emits about 254 g CO₂ per kWh (2025). Largest sources: gas 34.9%, wind 25%, solar 21.1%.

Who operates Eurofiber Datacenter Utrecht 1?

Eurofiber.