FIBERSTATE Salt Lake City (SLC1)

FIBERSTATE Salt Lake City (SLC1) is an operational data center operated by FIBERSTATE in Draper, United States. Our footprint estimate of its power is about 0.9 MW.

Key facts

StatusOperational
OperatorFIBERSTATE
Facility power0.9 MW (range 0.4 MW to 1.4 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 743 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 380 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks24 networks, 1 internet exchanges
PeeringDB.
Also known asFiberState Datacenter
Address106 E 13200 S
Coordinates40.51181, -111.88797
Websitefiberstate.com

Power and grid

Nearest high-voltage substationUnnamed substation, 138 kV, 2.3 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationCamp Williams Substation, 345 kV, 7.1 km away
HV substations within 10 km18
UtilityPacificorp (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPACW, PACE
Nearest gas pipelineKern River Gas Trans Co, interstate pipeline, 10.3 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km3.0 GW in 17 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity620 g CO₂ per kWh (Utah, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 46.9%, gas 30%, solar 17.4%, wind 2.1%, hydro 1.7%. Clean power: 22.6%
Industrial power priceUSD 0.086 per kWh (Utah, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature9.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.1 °C (2001 to 2025)
Cooling degree days469 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.8 kWh per m² per day
Wind at 50 m3.7 m/s average
Water stress todayHigh (40-80%) (Utah)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does FIBERSTATE Salt Lake City (SLC1) use?

We estimate the facility power at about 0.9 MW. Estimate from building footprint, low confidence.

How close is FIBERSTATE Salt Lake City (SLC1) to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 2.3 km away. The local utility is Pacificorp, in the PACW, PACE balancing area.

How clean is the power for FIBERSTATE Salt Lake City (SLC1)?

The grid in Utah emits about 620 g CO₂ per kWh (2025). Largest sources: coal 46.9%, gas 30%, solar 17.4%.

Who operates FIBERSTATE Salt Lake City (SLC1)?

FIBERSTATE.