Aligned Salt Lake (SLC-02)
Aligned Salt Lake (SLC-02) is an operational data center operated by Aligned Data Centers in South West Jordan, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Aligned Data Centers |
| Networks | 6 networks PeeringDB. |
| Also known as | Aligned Salt Lake (SLC-01) |
| Address | 3333 West 9000 |
| Coordinates | 40.58594, -111.96976 |
| Website | aligneddc.com/salt-lake-city |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 138 kV, 200 m away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | 90th South Substation, 345 kV, 4.5 km away |
| HV substations within 10 km | 31 |
| Utility | Pacificorp (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PACW, PACE |
| Nearest gas pipeline | Kern River Gas Trans Co, interstate pipeline, 4.8 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.5 GW in 15 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 620 g CO₂ per kWh (Utah, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 46.9%, gas 30%, solar 17.4%, wind 2.1%, hydro 1.7%. Clean power: 22.6% |
| Industrial power price | USD 0.086 per kWh (Utah, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.1 °C (2001 to 2025) |
| Cooling degree days | 469 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.8 kWh per m² per day |
| Wind at 50 m | 3.7 m/s average |
| Water stress today | High (40-80%) (Utah) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Aligned Salt Lake (SLC-02) to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 200 m away. The local utility is Pacificorp, in the PACW, PACE balancing area.
How clean is the power for Aligned Salt Lake (SLC-02)?
The grid in Utah emits about 620 g CO₂ per kWh (2025). Largest sources: coal 46.9%, gas 30%, solar 17.4%.
Who operates Aligned Salt Lake (SLC-02)?
Aligned Data Centers.
Data centers near South West Jordan
- Flexential - Salt Lake City/South Valley (SLC09) 4.0 km · 2.6 MW
- Verizon 5.6 km · 1.3 MW
- eBay 7.0 km · 33 MW
- Ebay 7.2 km · 14 MW
- FIBERSTATE Salt Lake City (SLC1) 10.8 km · 0.9 MW
- DataBank Salt Lake City (SLC2) 13.0 km · 21 MW
- Flexential - Salt Lake City/Millcreek (SLC10) 13.2 km · 5.7 MW
- Senawave 14.0 km
More Aligned Data Centers data centers
- Aligned Ashburn (IAD-02) United States
- Aligned Data Centers United States
- Aligned Phoenix (PHX-01) United States
- Aligned Data Centers DFW-04 United States
- Alinged Data Center DFW-03 United States
- Aligned DC - PDX-01 United States
- Aligned Data Centers United States
- Aligned Dallas (DFW-01) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.