Flexential - Salt Lake City/Millcreek (SLC10)

Flexential - Salt Lake City/Millcreek (SLC10) is an operational data center operated by Flexential in Salt Lake City, United States. Our footprint estimate of its power is about 5.7 MW.

Key facts

StatusOperational
OperatorFlexential
Facility power5.7 MW (range 2.9 MW to 9.2 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 4,773 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 2,400 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks2 networks
PeeringDB.
Also known asFlexential Salt Lake City - Millcreek
Address3949 S 200 E Ste B1
Coordinates40.68549, -111.88506
Websiteflexential.com

Power and grid

Nearest high-voltage substationUnnamed substation, 138 kV, 700 m away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationMid-Valley Substation, 345 kV, 4.4 km away
HV substations within 10 km34
UtilityPacificorp (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPACW, PACE
Nearest gas pipelineKern River Gas Trans Co, interstate pipeline, 12.8 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km2.5 GW in 16 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity620 g CO₂ per kWh (Utah, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 46.9%, gas 30%, solar 17.4%, wind 2.1%, hydro 1.7%. Clean power: 22.6%
Industrial power priceUSD 0.086 per kWh (Utah, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature9.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.1 °C (2001 to 2025)
Cooling degree days469 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.8 kWh per m² per day
Wind at 50 m3.7 m/s average
Water stress todayHigh (40-80%) (Utah)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Flexential - Salt Lake City/Millcreek (SLC10) use?

We estimate the facility power at about 5.7 MW. Estimate from building footprint, low confidence.

How close is Flexential - Salt Lake City/Millcreek (SLC10) to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 700 m away. The local utility is Pacificorp, in the PACW, PACE balancing area.

How clean is the power for Flexential - Salt Lake City/Millcreek (SLC10)?

The grid in Utah emits about 620 g CO₂ per kWh (2025). Largest sources: coal 46.9%, gas 30%, solar 17.4%.

Who operates Flexential - Salt Lake City/Millcreek (SLC10)?

Flexential.