DataBank Salt Lake City (SLC1)
DataBank Salt Lake City (SLC1) is an operational data center operated by DataBank in Salt Lake City, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | DataBank |
| Networks | 48 networks, 3 internet exchanges PeeringDB. |
| Address | 179 Social Hall Avenue |
| Coordinates | 40.76852, -111.88583 |
| Website | databank.com/data-centers/salt-lake-city/slc1 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 138 kV, 1.4 km away (Rocky Mountain Power) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Mid-Valley Substation, 345 kV, 7.7 km away |
| HV substations within 10 km | 25 |
| Utility | Pacificorp (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PACW, PACE |
| Nearest gas pipeline | Kern River Gas Trans Co, interstate pipeline, 10.5 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.5 GW in 17 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 620 g CO₂ per kWh (Utah, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 46.9%, gas 30%, solar 17.4%, wind 2.1%, hydro 1.7%. Clean power: 22.6% |
| Industrial power price | USD 0.086 per kWh (Utah, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 8.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 37.9 °C (2001 to 2025) |
| Cooling degree days | 365 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.78 kWh per m² per day |
| Wind at 50 m | 3.6 m/s average |
| Water stress today | High (40-80%) (Utah) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is DataBank Salt Lake City (SLC1) to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 1.4 km away. The local utility is Pacificorp, in the PACW, PACE balancing area.
How clean is the power for DataBank Salt Lake City (SLC1)?
The grid in Utah emits about 620 g CO₂ per kWh (2025). Largest sources: coal 46.9%, gas 30%, solar 17.4%.
Who operates DataBank Salt Lake City (SLC1)?
DataBank.
Data centers near Salt Lake City
- UFN Kearns 541 m
- XMission - Salt Lake City - Utah 885 m
- Recursion BioHive-2 1.4 km · 0.7 MW
- Flexential - Salt Lake City/Fairpark (SLC07) 2.9 km · 1.2 MW
- Flexential - Salt Lake City/Downtown (SLC04) 5.9 km
- Level(3) Salt Lake City 6.0 km · 5.5 MW
- Lowest Host/Empire Technology 6.2 km
- XO Salt Lake City IP PoP 8.2 km
More DataBank data centers
- Databank Orangeburg (LGA3) United States
- DataBank Salt Lake City (SLC2) United States
- DataBank Ashburn (IAD1) United States
- DataBank Dallas (DFW3) United States
- DataBank Las Vegas (LAS1) United States
- DataBank Dallas (DFW4) United States
- DataBank Minneapolis (MSP3) United States
- DataBank Seattle (SEA2) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.