Data Center Directory

Level(3) Salt Lake City

Level(3) Salt Lake City is an operational data center operated by Lumen Technologies in Salt Lake City, United States. Our footprint estimate of its power is about 5.5 MW.

Key facts

StatusOperational
OperatorLumen Technologies
Facility power5.5 MW (range 2.8 MW to 8.9 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 4,611 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 2,400 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks10 networks, 2 internet exchanges
PeeringDB.
Also known asFlexential Salt Lake City - Downtown
Address572 Delong Street
Coordinates40.75632, -111.95503
Websitelevel3.com

Power and grid

Nearest high-voltage substationGadsby Substation, 138 kV, 2.4 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationTerminal substation, 345 kV, 4.3 km away
HV substations within 10 km31
UtilityPacificorp (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPACW, PACE
Nearest gas pipelineKern River Gas Trans Co, interstate pipeline, 5.2 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km1.1 GW in 16 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity200 g CO₂ per kWh (Oregon, 2025)
Average of all power made in the area. Ember.
Grid power mixhydro 44.6%, gas 33.9%, wind 14.5%, solar 5.2%, bioenergy 1.6%. Clean power: 66.2%
Industrial power priceUSD 0.087 per kWh (Oregon, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature8.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature37.9 °C (2001 to 2025)
Cooling degree days365 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.78 kWh per m² per day
Wind at 50 m3.6 m/s average
Water stress todayLow - Medium (10-20%) (Oregon)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Level(3) Salt Lake City use?

We estimate the facility power at about 5.5 MW. Estimate from building footprint, low confidence.

How close is Level(3) Salt Lake City to the power grid?

The nearest high-voltage substation in OpenStreetMap is Gadsby Substation (138 kV), about 2.4 km away. The local utility is Pacificorp, in the PACW, PACE balancing area.

How clean is the power for Level(3) Salt Lake City?

The grid in Oregon emits about 200 g CO₂ per kWh (2025). Largest sources: hydro 44.6%, gas 33.9%, wind 14.5%.

Who operates Level(3) Salt Lake City?

Lumen Technologies.