Data Center Directory

Lowest Host/Empire Technology

Lowest Host/Empire Technology is an operational data center operated by Lowest Host/Empire Technology in Salt Lake City, United States. No power figure is public for this site yet.

Key facts

StatusOperational
OperatorLowest Host/Empire Technology
Address1394 N Morton Dr
Coordinates40.79970, -111.94691
Websiteempire-hosting.net

Power and grid

Nearest high-voltage substationUnnamed substation, 138 kV, 3.7 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationTerminal substation, 345 kV, 6.9 km away
HV substations within 10 km23
UtilityPacificorp (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPACW, PACE
Nearest gas pipelineKern River Gas Trans Co, interstate pipeline, 4.6 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km1.1 GW in 16 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity620 g CO₂ per kWh (Utah, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 46.9%, gas 30%, solar 17.4%, wind 2.1%, hydro 1.7%. Clean power: 22.6%
Industrial power priceUSD 0.086 per kWh (Utah, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature8.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature37.9 °C (2001 to 2025)
Cooling degree days365 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.78 kWh per m² per day
Wind at 50 m3.6 m/s average
Water stress todayHigh (40-80%) (Utah)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How close is Lowest Host/Empire Technology to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 3.7 km away. The local utility is Pacificorp, in the PACW, PACE balancing area.

How clean is the power for Lowest Host/Empire Technology?

The grid in Utah emits about 620 g CO₂ per kWh (2025). Largest sources: coal 46.9%, gas 30%, solar 17.4%.

Who operates Lowest Host/Empire Technology?

Lowest Host/Empire Technology.