EdgeConneX Salt Lake City (EDCSLC01)
EdgeConneX Salt Lake City (EDCSLC01) is an operational data center operated by EdgeConneX in Salt Lake City, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | EdgeConneX |
| Networks | 18 networks, 3 internet exchanges PeeringDB. |
| Also known as | Voonami SLC2 |
| Address | 2302 Presidents Drive |
| Coordinates | 40.72087, -111.98493 |
| Website | edgeconnex.com |
Power and grid
| Nearest high-voltage substation | Ridgeland Substation, 138 kV, 300 m away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Terminal substation, 345 kV, 4.5 km away |
| HV substations within 10 km | 32 |
| Utility | Pacificorp (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PACW, PACE |
| Nearest gas pipeline | Kern River Gas Trans Co, interstate pipeline, 3.7 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.5 GW in 16 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 620 g CO₂ per kWh (Utah, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 46.9%, gas 30%, solar 17.4%, wind 2.1%, hydro 1.7%. Clean power: 22.6% |
| Industrial power price | USD 0.086 per kWh (Utah, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.1 °C (2001 to 2025) |
| Cooling degree days | 469 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.8 kWh per m² per day |
| Wind at 50 m | 3.7 m/s average |
| Water stress today | High (40-80%) (Utah) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is EdgeConneX Salt Lake City (EDCSLC01) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Ridgeland Substation (138 kV), about 300 m away. The local utility is Pacificorp, in the PACW, PACE balancing area.
How clean is the power for EdgeConneX Salt Lake City (EDCSLC01)?
The grid in Utah emits about 620 g CO₂ per kWh (2025). Largest sources: coal 46.9%, gas 30%, solar 17.4%.
Who operates EdgeConneX Salt Lake City (EDCSLC01)?
EdgeConneX.
Data centers near Salt Lake City
- Senawave 2.0 km
- XO Salt Lake City IP PoP 3.4 km
- Level(3) Salt Lake City 4.7 km · 5.5 MW
- Flexential - Salt Lake City/Downtown (SLC04) 4.7 km
- Flexential - Salt Lake City/Fairpark (SLC07) 7.5 km · 1.2 MW
- Recursion BioHive-2 8.7 km · 0.7 MW
- XMission - Salt Lake City - Utah 9.2 km
- Flexential - Salt Lake City/Millcreek (SLC10) 9.3 km · 5.7 MW
More EdgeConneX data centers
- EdgeConneX PHX02 Data Center United States
- EdgeConneX data center in Oosteinde Netherlands
- EdgeConnex DUB04 Ireland
- EdgeConneX Germany
- EdgeConneX Chicago (EDCCHI02) United States
- EdgeConneX data center in Oosteinde Netherlands
- EdgeConneX data center in Oosteinde Netherlands
- EdgeConnex - DEN02 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.