Global Switch Amsterdam
Global Switch Amsterdam is an operational data center operated by Global Switch in Amsterdam, Netherlands. Our footprint estimate of its power is about 32 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Global Switch |
| Facility power | 32 MW (range 16 MW to 51 MW) Estimate from building footprint, low confidence. Footprint estimate: about 26,393 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 14,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 99 networks, 5 internet exchanges PeeringDB. |
| Address | Johan Huizingalaan 759 |
| Opened | 1969 |
| Coordinates | 52.34398, 4.82871 |
| Website | globalswitch.com/locations/amsterdam |
Power and grid
| Grid carbon intensity | 254 g CO₂ per kWh (Netherlands, 2025) Average of all power made in the area. Ember. |
|---|---|
| Grid power mix | gas 34.9%, wind 25%, solar 21.1%, coal 7.1%, bioenergy 5.1%. Clean power: 54.2% |
| Industrial power price | EUR 0.139 per kWh (Netherlands, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 32.1 °C (2001 to 2025) |
| Cooling degree days | 53 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.97 kWh per m² per day |
| Wind at 50 m | 7.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Netherlands) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Global Switch Amsterdam use?
We estimate the facility power at about 32 MW. Estimate from building footprint, low confidence.
How clean is the power for Global Switch Amsterdam?
The grid in Netherlands emits about 254 g CO₂ per kWh (2025). Largest sources: gas 34.9%, wind 25%, solar 21.1%.
Who operates Global Switch Amsterdam?
Global Switch.
Data centers near Amsterdam
- Zayo Amsterdam 1.6 km
- KPN DC2 4.0 km · 4.7 MW
- XS4ALL Oude Meer 5.1 km
- NorthC Amsterdam 1 5.6 km
- Equinix AM8 - Amsterdam, Gyroscoopweg 5.9 km · 1 MW
- Databarn Amsterdam 6.0 km · 0.8 MW
- Qupra DC 6.2 km
- euNetworks Amsterdam 6.3 km · 11 MW
More Global Switch data centers
- Global Switch Singapore Singapore
- Global Switch London East United Kingdom
- Global Switch Paris France
- Global Switch Frankfurt Germany
- Global Switch Hong Kong Hong Kong SAR China
- Global Switch London North United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.