Global Switch London East

Global Switch London East is an operational data center operated by Global Switch in London, United Kingdom. Our footprint estimate of its power is about 38 MW.

Key facts

StatusOperational
OperatorGlobal Switch
Facility power38 MW (range 19 MW to 61 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 10,523 m² building outline x 3 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 16,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks31 networks, 1 internet exchanges
PeeringDB.
Also known asEXA Datacenter London (GS2 London East) · Global Switch London North
Address3 Nutmeg Lane
Coordinates51.51098, -0.00349
Websiteglobalswitch.com

Power and grid

Nearest high-voltage substationTelehouse Substation, 132 kV, 100 m away (Telehouse)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationWest Ham Substation, 400 kV, 1 km away
HV substations within 10 km52
Power plants within 50 km3.1 GW in 97 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity218 g CO₂ per kWh (United Kingdom, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2%

Climate and water

Average temperature10.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature34 °C (2001 to 2025)
Cooling degree days46 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.97 kWh per m² per day
Wind at 50 m7.2 m/s average
Water stress todayLow - Medium (10-20%) (England)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Global Switch London East use?

We estimate the facility power at about 38 MW. Estimate from building footprint, low confidence.

How close is Global Switch London East to the power grid?

The nearest high-voltage substation in OpenStreetMap is Telehouse Substation (132 kV), about 100 m away.

How clean is the power for Global Switch London East?

The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.

Who operates Global Switch London East?

Global Switch.

Data centers near London

More Global Switch data centers