Telehouse - London (Docklands South)

Telehouse - London (Docklands South) is an operational data center operated by Telehouse - Global Data Centers in London, United Kingdom. Our footprint estimate of its power is about 37 MW.

Key facts

StatusOperational
OperatorTelehouse - Global Data Centers
Facility power37 MW (range 18 MW to 58 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 5,070 m² building outline x 6 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 16,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks39 networks, 4 internet exchanges
PeeringDB.
Also known asTelehouse South
Address1 Blackwall Way, Paul Julius Close
Coordinates51.50704, -0.00339
Websitetelehouse.net/data-centre-services/uk/london/telehouse-south

Power and grid

Nearest high-voltage substationBlackwall Way Substation, 132 kV, 100 m away (UK Power Networks)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationWest Ham Substation, 400 kV, 1.4 km away
HV substations within 10 km52
Power plants within 50 km3.1 GW in 96 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity218 g CO₂ per kWh (United Kingdom, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2%

Climate and water

Average temperature10.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature34 °C (2001 to 2025)
Cooling degree days46 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.97 kWh per m² per day
Wind at 50 m7.2 m/s average
Water stress todayLow - Medium (10-20%) (England)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Telehouse - London (Docklands South) use?

We estimate the facility power at about 37 MW. Estimate from building footprint, low confidence.

How close is Telehouse - London (Docklands South) to the power grid?

The nearest high-voltage substation in OpenStreetMap is Blackwall Way Substation (132 kV), about 100 m away.

How clean is the power for Telehouse - London (Docklands South)?

The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.

Who operates Telehouse - London (Docklands South)?

Telehouse - Global Data Centers.