Telehouse - Frankfurt
Telehouse - Frankfurt is an operational data center operated by Telehouse - Global Data Centers in Frankfurt, Germany. Our footprint estimate of its power is about 3.2 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Telehouse - Global Data Centers |
| Facility power | 3.2 MW (range 1.6 MW to 5.1 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,662 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,400 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 80 networks, 5 internet exchanges PeeringDB. |
| Address | Kleyerstrasse 75-87 |
| Coordinates | 50.09696, 8.63006 |
| Website | telehouse-rechenzentrum.de |
Power and grid
| Nearest high-voltage substation | Umspannwerk Kleyerstraße, 110 kV, 300 m away (Netzdienste Rhein-Main) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Frankfurt Südwest, 380 kV, 1 km away |
| HV substations within 10 km | 36 |
| Power plants within 50 km | 3.3 GW in 42 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Telehouse - Frankfurt use?
We estimate the facility power at about 3.2 MW. Estimate from building footprint, low confidence.
How close is Telehouse - Frankfurt to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Kleyerstraße (110 kV), about 300 m away.
How clean is the power for Telehouse - Frankfurt?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Telehouse - Frankfurt?
Telehouse - Global Data Centers.
Data centers near Frankfurt
- Telehouse data center in Frankfurt am Main 97 m · 13 MW
- Equinix FR5 - Frankfurt, KleyerStrasse 252 m · 37 MW
- ITENOS Frankfurt (FRA1) 328 m · 14 MW
- aixit Frankfurt 439 m · 7.4 MW
- 3U Rechenzentrum Frankfurt 441 m
- Lumen Frankfurt 2 493 m
- NewColo Frankfurt 608 m
- ColoCenter Frankfurt 849 m
More Telehouse - Global Data Centers data centers
- Telehouse - London (Docklands South) United Kingdom
- Telehouse - Hong Kong CCC (HKCOLO TKO) Hong Kong SAR China
- Telehouse – Bangkok Thailand
- Telehouse - Beijing BDA China
- Telehouse - Beijing BEZ China
- Telehouse - Hanoi Vietnam
- Telehouse - Los Angeles United States
- Telehouse - Paris 1 (Jeûneurs) France
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.