Telehouse data center in Frankfurt am Main
Telehouse data center in Frankfurt am Main is an operational data center operated by Telehouse in Frankfurt am Main, Germany. Our footprint estimate of its power is about 13 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Telehouse |
| Facility power | 13 MW (range 6.7 MW to 21 MW) Estimate from building footprint, low confidence. Footprint estimate: about 11,158 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 5,600 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Kleyerstraße 75-87, 60326, Frankfurt am Main |
| Coordinates | 50.09609, 8.62992 |
| Website | telehouse.net/data-centre-services/germany/frankfurt |
Power and grid
| Nearest high-voltage substation | Umspannwerk Kleyerstraße, 110 kV, 200 m away (Netzdienste Rhein-Main) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Frankfurt Südwest, 380 kV, 900 m away |
| HV substations within 10 km | 36 |
| Power plants within 50 km | 3.3 GW in 42 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Telehouse data center in Frankfurt am Main use?
We estimate the facility power at about 13 MW. Estimate from building footprint, low confidence.
How close is Telehouse data center in Frankfurt am Main to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Kleyerstraße (110 kV), about 200 m away.
How clean is the power for Telehouse data center in Frankfurt am Main?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Telehouse data center in Frankfurt am Main?
Telehouse.
Data centers near Frankfurt am Main
- Telehouse - Frankfurt 97 m · 3.2 MW
- Equinix FR5 - Frankfurt, KleyerStrasse 341 m · 37 MW
- ITENOS Frankfurt (FRA1) 422 m · 14 MW
- 3U Rechenzentrum Frankfurt 497 m
- aixit Frankfurt 535 m · 7.4 MW
- Lumen Frankfurt 2 575 m
- NewColo Frankfurt 698 m
- ColoCenter Frankfurt 938 m
More Telehouse data centers
- Telehouse North United Kingdom
- Telehouse Teleport United States
- Telehouse 3 France
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.