ITENOS Frankfurt (FRA1)
ITENOS Frankfurt (FRA1) is an operational data center operated by ITENOS in Frankfurt, Germany. Our footprint estimate of its power is about 14 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | ITENOS |
| Facility power | 14 MW (range 7.1 MW to 23 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,960 m² building outline x 6 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 6,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 76 networks, 9 internet exchanges PeeringDB. |
| Also known as | NewTelco Frankfurt · I.T.E.N.O.S. Frankfurt - C · I.T.E.N.O.S. Frankfurt - B |
| Address | Kleyerstrasse 90 / Rebstoeckerstrasse 25-31 |
| Coordinates | 50.09970, 8.63176 |
| Website | itenos.de/en/datacenter/data-center-germany/data-center-frankfurt-1 |
Power and grid
| Nearest high-voltage substation | Umspannwerk Kleyerstraße, 110 kV, 600 m away (Netzdienste Rhein-Main) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Frankfurt Südwest, 380 kV, 1.3 km away |
| HV substations within 10 km | 37 |
| Power plants within 50 km | 3.3 GW in 43 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does ITENOS Frankfurt (FRA1) use?
We estimate the facility power at about 14 MW. Estimate from building footprint, low confidence.
How close is ITENOS Frankfurt (FRA1) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Kleyerstraße (110 kV), about 600 m away.
How clean is the power for ITENOS Frankfurt (FRA1)?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates ITENOS Frankfurt (FRA1)?
ITENOS.
Data centers near Frankfurt
- Equinix FR5 - Frankfurt, KleyerStrasse 96 m · 37 MW
- aixit Frankfurt 205 m · 7.4 MW
- Lumen Frankfurt 2 214 m
- NewColo Frankfurt 288 m
- 3U Rechenzentrum Frankfurt 306 m
- Telehouse - Frankfurt 328 m · 3.2 MW
- Telehouse data center in Frankfurt am Main 422 m · 13 MW
- ColoCenter Frankfurt 529 m
More ITENOS data centers
- ITENOS Hamburg (HAM1) Germany
- ITENOS Leverkusen (LEV1) Germany
- ITENOS Stuttgart (STR1) Germany
- ITENOS Stuttgart (STR2) Germany
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.