GTN Data Center
GTN Data Center is an operational data center operated by Graha Teknologi Nusantara in Cikarang, Indonesia. Our footprint estimate of its power is about 6 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Graha Teknologi Nusantara |
| Facility power | 6 MW (range 3 MW to 9.6 MW) Estimate from building footprint, low confidence. Footprint estimate: about 5,018 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,600 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | -6.34602, 107.16708 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 150 kV, 2.4 km away (Perusahaan Listrik Negara) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 500 kV, 3.6 km away |
| HV substations within 10 km | 13 |
| Power plants within 50 km | 12 GW in 24 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 705 g CO₂ per kWh (Indonesia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 69.4%, gas 11.6%, hydro 6.7%, bioenergy 5.3%, other renewables 3.4%. Clean power: 15.8% |
Climate and water
| Average temperature | 24.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.3 °C (2001 to 2025) |
| Cooling degree days | 2,507 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.01 kWh per m² per day |
| Wind at 50 m | 3.1 m/s average |
| Water stress today | Medium - High (20-40%) (Indonesia) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does GTN Data Center use?
We estimate the facility power at about 6 MW. Estimate from building footprint, low confidence.
How close is GTN Data Center to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (150 kV), about 2.4 km away.
How clean is the power for GTN Data Center?
The grid in Indonesia emits about 705 g CO₂ per kWh (2025). Largest sources: coal 69.4%, gas 11.6%, hydro 6.7%.
Who operates GTN Data Center?
Graha Teknologi Nusantara.
Data centers near Cikarang
- Graha Teknologi Bekasi 262 m
- Hyperscale Data Center (HDC) 3.5 km
- Digital Hyperspace Jakarta 3.8 km · 6.7 MW
- DIgital Edge CGK Campus 4.0 km
- Microsoft JKT05 4.1 km · 14 MW
- Princeton Digital JC3 4.1 km · 14 MW
- Amazon Web Services 4.4 km · 9.6 MW
- STTGDC JKT1 4.9 km
More Graha Teknologi Nusantara data centers
- Graha Teknologi Bekasi Indonesia
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.