IXcellerate MOS2
IXcellerate MOS2 is an operational data center operated by IXcellerate in Moscow, Russia. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | IXcellerate |
| Networks | 2 networks PeeringDB. |
| Also known as | IXcellerate MOS3 · IXcellerate MOS4 |
| Address | Altufievskoe shosse 33G |
| Coordinates | 55.86325, 37.60907 |
| Website | ixcellerate.com/data-centers/moscow-north-campus/#mos2 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 500 kV, 1.6 km away (ФСК ЕЭС) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 47 |
| Power plants within 50 km | 13 GW in 26 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 447 g CO₂ per kWh (Russia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 45.6%, nuclear 18.3%, coal 17.7%, hydro 16.7%, oil and other fossil 1%. Clean power: 35.7% |
Climate and water
| Average temperature | 4.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.1 °C (2001 to 2025) |
| Cooling degree days | 86 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.8 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Russia) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is IXcellerate MOS2 to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (500 kV), about 1.6 km away.
How clean is the power for IXcellerate MOS2?
The grid in Russia emits about 447 g CO₂ per kWh (2025). Largest sources: gas 45.6%, nuclear 18.3%, coal 17.7%.
Who operates IXcellerate MOS2?
IXcellerate.
Data centers near Moscow
- 3data A35 1.7 km
- IXcellerate MOS1 2.0 km · 21 MW
- Rostelecom Moscow-V 2.8 km · 29 MW
- e-Style ISP LLC 3.0 km
- Tech.ru DC2 5.3 km
- ЦОД "Гознак" 5.7 km
- NORD-4 6.5 km · 5.2 MW
- Data center in Novokhovrino 6.7 km · 3.1 MW
More IXcellerate data centers
- IXcellerate South MOS5 Russia
- IXcellerate MOS1 Russia
- IXcellerate MOS5 Russia