IXcellerate South MOS5
IXcellerate South MOS5 is an operational data center operated by IXcellerate in Biryulëvo Zapadnoye, Russia. Our footprint estimate of its power is about 32 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | IXcellerate |
| Facility power | 32 MW (range 16 MW to 51 MW) Estimate from building footprint, low confidence. Footprint estimate: about 26,465 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 14,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | улица Подольских Курсантов 15Б с1 |
| Coordinates | 55.60302, 37.64400 |
| Website | ixcellerate.com/data-centers/moscow-south-campus |
Power and grid
| Nearest high-voltage substation | Царицыно, 110 kV, 800 m away (ОАО «РЖД») Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Чертаново, 220 kV, 1.2 km away |
| HV substations within 10 km | 46 |
| Power plants within 50 km | 13 GW in 26 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 447 g CO₂ per kWh (Russia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 45.6%, nuclear 18.3%, coal 17.7%, hydro 16.7%, oil and other fossil 1%. Clean power: 35.7% |
Climate and water
| Average temperature | 4.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.3 °C (2001 to 2025) |
| Cooling degree days | 92 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.86 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Russia) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does IXcellerate South MOS5 use?
We estimate the facility power at about 32 MW. Estimate from building footprint, low confidence.
How close is IXcellerate South MOS5 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Царицыно (110 kV), about 800 m away.
How clean is the power for IXcellerate South MOS5?
The grid in Russia emits about 447 g CO₂ per kWh (2025). Largest sources: gas 45.6%, nuclear 18.3%, coal 17.7%.
Who operates IXcellerate South MOS5?
IXcellerate.
Data centers near Biryulëvo Zapadnoye
- Data center in Biryulëvo Zapadnoye 174 m · 4.8 MW
- Nubes Alto 465 m
- IXcellerate MOS5 1.3 km
- M1 StackTelecom Datacenter 3.0 km
- DataHouse Moscow 8.0 km
- SPACE-IX 8.1 km
- 3data B17 8.2 km
- Tech.ru DC4 8.4 km
More IXcellerate data centers
- IXcellerate MOS1 Russia
- IXcellerate MOS2 Russia
- IXcellerate MOS5 Russia