KoloDC NL3
KoloDC NL3 is an operational data center operated by KoloDC in Apeldoorn, Netherlands. Our footprint estimate of its power is about 2.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | KoloDC |
| Facility power | 2.1 MW (range 1 MW to 3.3 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,734 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 900 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 13 networks, 1 internet exchanges PeeringDB. |
| Also known as | Kolo NL3 Apeldoorn |
| Address | Laan van de Ram 39 |
| Opened | 2009 |
| Coordinates | 52.24703, 6.00160 |
| Website | kolodc.com |
Power and grid
| Nearest high-voltage substation | 150 kV Zuidbroek, 150 kV, 100 m away (TenneT) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | 380 kV Zwolle, 380 kV, 34 km away |
| HV substations within 10 km | 5 |
| Power plants within 50 km | 2.7 GW in 109 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 254 g CO₂ per kWh (Netherlands, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 34.9%, wind 25%, solar 21.1%, coal 7.1%, bioenergy 5.1%. Clean power: 54.2% |
| Industrial power price | EUR 0.139 per kWh (Netherlands, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 36.7 °C (2001 to 2025) |
| Cooling degree days | 83 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.9 kWh per m² per day |
| Wind at 50 m | 6.7 m/s average |
| Water stress today | Low (<10%) (Gelderland) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does KoloDC NL3 use?
We estimate the facility power at about 2.1 MW. Estimate from building footprint, low confidence.
How close is KoloDC NL3 to the power grid?
The nearest high-voltage substation in OpenStreetMap is 150 kV Zuidbroek (150 kV), about 100 m away.
How clean is the power for KoloDC NL3?
The grid in Netherlands emits about 254 g CO₂ per kWh (2025). Largest sources: gas 34.9%, wind 25%, solar 21.1%.
Who operates KoloDC NL3?
KoloDC.
Data centers near Apeldoorn
- ITB2 Datacenter Apeldoorn 5.4 km
- Cellnex 11.3 km
- ITB2 Datacenter Deventer 13.2 km
- Equinix ZW1 - Zwolle 28.5 km
- Eurofiber Datacenter Arnhem 1 29.2 km
- Eurofiber data center Arnhem 1 29.3 km
- Qonnected II Markelo (Cellnex) 30.0 km
- Datacenter Arnhem KLW 31.1 km
More KoloDC data centers
- KoloDC NL1 Netherlands
- KoloDC NL2 Netherlands
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.