Matrix Data Center JK3 (MDC JK3)
Matrix Data Center JK3 (MDC JK3) is an operational data center operated by PT. NAP Info Lintas Nusa in Jakarta Selatan, Indonesia. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | PT. NAP Info Lintas Nusa |
| Networks | 14 networks, 3 internet exchanges PeeringDB. |
| Address | Plaza Kuningan Annex Building, Jl. HR. Rasuna Said Kav.C11-14, Karet Kuningan, Setiabudi |
| Coordinates | -6.21684, 106.83146 |
| Website | napinfo.co.id |
Power and grid
| Nearest high-voltage substation | GIS Setiabudi, 150 kV, 300 m away (Perusahaan Listrik Negara) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | GISTET Kembangan, 500 kV, 12.7 km away |
| HV substations within 10 km | 31 |
| Power plants within 50 km | 10 GW in 15 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 705 g CO₂ per kWh (Indonesia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 69.4%, gas 11.6%, hydro 6.7%, bioenergy 5.3%, other renewables 3.4%. Clean power: 15.8% |
Climate and water
| Average temperature | 27.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34.2 °C (2001 to 2025) |
| Cooling degree days | 3,369 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.04 kWh per m² per day |
| Wind at 50 m | 3.9 m/s average |
| Water stress today | Medium - High (20-40%) (Indonesia) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Matrix Data Center JK3 (MDC JK3) to the power grid?
The nearest high-voltage substation in OpenStreetMap is GIS Setiabudi (150 kV), about 300 m away.
How clean is the power for Matrix Data Center JK3 (MDC JK3)?
The grid in Indonesia emits about 705 g CO₂ per kWh (2025). Largest sources: coal 69.4%, gas 11.6%, hydro 6.7%.
Who operates Matrix Data Center JK3 (MDC JK3)?
PT. NAP Info Lintas Nusa.
Data centers near Jakarta Selatan
- EDGE2 (EG2) - Digital Edge JKT2 - Jakarta 531 m · 30 MW
- Yellowstone Data Center 625 m · 44 MW
- NEX Datacenter (NEX-JK1) Jakarta 1.1 km
- DCI Indonesia (E1) 1.2 km
- Biznet MegaPOP Jakarta MidPlaza 1.5 km
- PSN Networks 1.8 km
- BDx CGK1 - Jakarta City Center 1.8 km
- NTT Indonesia Jakarta 2 1.9 km
More PT. NAP Info Lintas Nusa data centers
- Matrix Data Center BM1 (MDC BM1) Indonesia
- Matrix Data Center JK1 (MDC JK1) Indonesia
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.