Netrality Houston - 1301 Fannin
Netrality Houston - 1301 Fannin is an operational data center operated by Netrality Data Centers in Houston, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Netrality Data Centers |
| Networks | 30 networks, 6 internet exchanges PeeringDB. |
| Also known as | INAP Houston |
| Address | 1301 Fannin - Netrality Data Center Meet Me Room, 1301 Fannin Street |
| Coordinates | 29.75324, -95.36588 |
| Website | netrality.com/data-center/1301-fannin-houston |
Power and grid
| Nearest high-voltage substation | Polk Substation, 138 kV, 400 m away (CenterPoint Energy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Bellaire Substation, 345 kV, 8.8 km away |
| HV substations within 10 km | 33 |
| Utility | San Bernard Electric Coop, INC (cooperative) Electric retail service territory (HIFLD, US government). |
| Balancing authority | ERCO |
| Nearest gas pipeline | Kinder Morgan Texas Pipeline Co, intrastate pipeline, 6.6 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 21 GW in 54 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 20.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 42.7 °C (2001 to 2025) |
| Cooling degree days | 1,754 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.65 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Netrality Houston - 1301 Fannin to the power grid?
The nearest high-voltage substation in OpenStreetMap is Polk Substation (138 kV), about 400 m away. The local utility is San Bernard Electric Coop, INC, in the ERCO balancing area.
How clean is the power for Netrality Houston - 1301 Fannin?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates Netrality Houston - 1301 Fannin?
Netrality Data Centers.
Data centers near Houston
- InterConnX Realty 414 m
- Alpheus Houston (777 Walker Street) 666 m
- Quasar Data Center 841 m
- 3500 Garrott 2.3 km
- Databank Houston Galleria (HOU5) 8.1 km
- Data Foundry Houston 1 10.2 km
- Rice Data Center 13.0 km · 5 MW
- Equinix HO1 - Houston 20.3 km
More Netrality Data Centers data centers
- Netrality St. Louis - 210 N Tucker United States
- Netrality - Indy Telcom Center - 733 W. Henry United States
- Netrality Chicago - 717 S Wells United States
- Netrality Kansas City - 1102 Grand United States
- Netrality Kansas City Metro – KC2 | 7801 Nieman United States
- Netrality St. Louis - 900 Walnut United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.