NYSE Data Center

NYSE Data Center is an operational data center operated by nyse in Mahwah, United States. Our footprint estimate of its power is about 18 MW.

Key facts

StatusOperational
Operatornyse
Facility power18 MW (range 9.1 MW to 29 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 15,197 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 7,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Coordinates41.07832, -74.15291

Power and grid

Nearest high-voltage substationMacArthur Blvd, 138 kV, 100 m away (Orange & Rockland)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationSouth Mahwah, 345 kV, 900 m away
HV substations within 10 km11
UtilityRockland Electric Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM, NYIS
Nearest gas pipelineAlgonquin Gas Trans Co, interstate pipeline, 1.4 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km14 GW in 120 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity268 g CO₂ per kWh (New York, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 45.4%, nuclear 20.7%, hydro 18.5%, solar 7.6%, wind 5%. Clean power: 52.9%
Industrial power priceUSD 0.105 per kWh (New York, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature11.1 °C
NASA POWER, average of 2001 to 2025.
Highest temperature38.7 °C (2001 to 2025)
Cooling degree days504 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.87 kWh per m² per day
Wind at 50 m5.3 m/s average
Water stress todayLow - Medium (10-20%) (New York)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does NYSE Data Center use?

We estimate the facility power at about 18 MW. Estimate from building footprint, low confidence.

How close is NYSE Data Center to the power grid?

The nearest high-voltage substation in OpenStreetMap is MacArthur Blvd (138 kV), about 100 m away. The local utility is Rockland Electric Co, in the PJM, NYIS balancing area.

How clean is the power for NYSE Data Center?

The grid in New York emits about 268 g CO₂ per kWh (2025). Largest sources: gas 45.4%, nuclear 20.7%, hydro 18.5%.

Who operates NYSE Data Center?

nyse.