NYSE Data Center
NYSE Data Center is an operational data center operated by nyse in Mahwah, United States. Our footprint estimate of its power is about 18 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | nyse |
| Facility power | 18 MW (range 9.1 MW to 29 MW) Estimate from building footprint, low confidence. Footprint estimate: about 15,197 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 7,700 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 41.07832, -74.15291 |
Power and grid
| Nearest high-voltage substation | MacArthur Blvd, 138 kV, 100 m away (Orange & Rockland) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | South Mahwah, 345 kV, 900 m away |
| HV substations within 10 km | 11 |
| Utility | Rockland Electric Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM, NYIS |
| Nearest gas pipeline | Algonquin Gas Trans Co, interstate pipeline, 1.4 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 14 GW in 120 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 268 g CO₂ per kWh (New York, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 45.4%, nuclear 20.7%, hydro 18.5%, solar 7.6%, wind 5%. Clean power: 52.9% |
| Industrial power price | USD 0.105 per kWh (New York, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 11.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38.7 °C (2001 to 2025) |
| Cooling degree days | 504 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.87 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | Low - Medium (10-20%) (New York) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does NYSE Data Center use?
We estimate the facility power at about 18 MW. Estimate from building footprint, low confidence.
How close is NYSE Data Center to the power grid?
The nearest high-voltage substation in OpenStreetMap is MacArthur Blvd (138 kV), about 100 m away. The local utility is Rockland Electric Co, in the PJM, NYIS balancing area.
How clean is the power for NYSE Data Center?
The grid in New York emits about 268 g CO₂ per kWh (2025). Largest sources: gas 45.4%, nuclear 20.7%, hydro 18.5%.
Who operates NYSE Data Center?
nyse.
Data centers near Mahwah
- Databank Orangeburg (LGA3) 14.3 km · 21 MW
- Bloomberg Data Center 14.6 km · 31 MW
- Data center in Orangeburg 15.5 km · 32 MW
- ColoHouse New York 15.6 km · 16 MW
- JPMorgan Chase data center in Totowa 20.3 km · 30 MW
- CyrusOne Totowa 20.4 km · 15 MW
- WhiteLabelITSolutions 23.3 km
- Data center in Yonkers 25.6 km · 2.3 MW