OVH US East Vint Hill
OVH US East Vint Hill is an operational data center in New Baltimore, United States. Our footprint estimate of its power is about 9.6 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 9.6 MW (range 4.8 MW to 15 MW) Estimate from building footprint, low confidence. Footprint estimate: about 8,015 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Watson Court 6872, 20187 |
| Coordinates | 38.74742, -77.67446 |
Power and grid
| Nearest high-voltage substation | Wheeler Substation, 230 kV, 1.9 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 13 |
| Utility | Northern Virginia Elec Coop (cooperative) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Columbia Gas Trans Co, interstate pipeline, 1.2 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.9 GW in 17 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 357 g CO₂ per kWh (Virginia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39% |
| Industrial power price | USD 0.100 per kWh (Virginia, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 13.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.2 °C (2001 to 2025) |
| Cooling degree days | 808 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.12 kWh per m² per day |
| Wind at 50 m | 4.5 m/s average |
| Water stress today | Medium - High (20-40%) (Virginia) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does OVH US East Vint Hill use?
We estimate the facility power at about 9.6 MW. Estimate from building footprint, low confidence.
How close is OVH US East Vint Hill to the power grid?
The nearest high-voltage substation in OpenStreetMap is Wheeler Substation (230 kV), about 1.9 km away. The local utility is Northern Virginia Elec Coop, in the PJM balancing area.
How clean is the power for OVH US East Vint Hill?
The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.
Data centers near New Baltimore
- Digital Realty GNV (8217 Linton Hall) 7.5 km
- Amazon IAD-197 7.6 km · 27 MW
- Digital Realty VA4 7.7 km · 12 MW
- Amazon IAD-55 7.8 km · 37 MW
- Amazon Web Services data center in Gainesville 7.9 km · 15 MW
- NTT VA10 8.1 km · 122 MW
- Google Mango Farm 8.3 km · 60 MW
- Google Mango Farm Building 3 8.4 km · 62 MW
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.