Patmos KC2
Patmos KC2 is an operational data center operated by Patmos Hosting in Kansas City, United States. Our footprint estimate of its power is about 106 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Patmos Hosting |
| Facility power | 106 MW (range 53 MW to 170 MW) Estimate from building footprint, low confidence. Footprint estimate: about 14,726 m² building outline x 6 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 45,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | 1601 McGee St |
| Coordinates | 39.09474, -94.57938 |
| Website | patmos.tech |
Power and grid
| Nearest high-voltage substation | Crosstown Substation, 161 kV, 500 m away (Evergy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Hawthorn Substation, 345 kV, 9.4 km away |
| HV substations within 10 km | 33 |
| Utility | City Of Kansas City (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | SWPP |
| Nearest gas pipeline | Panhandle Eastern PL Co, interstate pipeline, 7.2 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 4.2 GW in 21 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 674 g CO₂ per kWh (Missouri, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 63.1%, gas 13%, nuclear 9.8%, wind 8.9%, solar 3.3%. Clean power: 23.7% |
| Industrial power price | USD 0.099 per kWh (Missouri, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 44.4 °C (2001 to 2025) |
| Cooling degree days | 784 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.23 kWh per m² per day |
| Wind at 50 m | 6.7 m/s average |
| Water stress today | Low - Medium (10-20%) (Missouri) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Patmos KC2 use?
We estimate the facility power at about 106 MW. Estimate from building footprint, low confidence.
How close is Patmos KC2 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Crosstown Substation (161 kV), about 500 m away. The local utility is City Of Kansas City, in the SWPP balancing area.
How clean is the power for Patmos KC2?
The grid in Missouri emits about 674 g CO₂ per kWh (2025). Largest sources: coal 63.1%, gas 13%, nuclear 9.8%.
Who operates Patmos KC2?
Patmos Hosting.
Data centers near Kansas City
- Google Kansas City East 606 m · 126 MW
- Level(3) Kansas City 694 m
- Netrality Kansas City - 1102 Grand 704 m
- Oak Tower 713 m
- Lumen Kansas City 1.0 km
- Patmos KC1 1.1 km
- ProRacks Datacenter- Kansas City 1.5 km
- UnReal Servers 4.3 km