Patmos KC2

Patmos KC2 is an operational data center operated by Patmos Hosting in Kansas City, United States. Our footprint estimate of its power is about 106 MW.

Key facts

StatusOperational
OperatorPatmos Hosting
Facility power106 MW (range 53 MW to 170 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 14,726 m² building outline x 6 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 45,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Address1601 McGee St
Coordinates39.09474, -94.57938
Websitepatmos.tech

Power and grid

Nearest high-voltage substationCrosstown Substation, 161 kV, 500 m away (Evergy)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationHawthorn Substation, 345 kV, 9.4 km away
HV substations within 10 km33
UtilityCity Of Kansas City (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authoritySWPP
Nearest gas pipelinePanhandle Eastern PL Co, interstate pipeline, 7.2 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km4.2 GW in 21 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity674 g CO₂ per kWh (Missouri, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 63.1%, gas 13%, nuclear 9.8%, wind 8.9%, solar 3.3%. Clean power: 23.7%
Industrial power priceUSD 0.099 per kWh (Missouri, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature12.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature44.4 °C (2001 to 2025)
Cooling degree days784 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.23 kWh per m² per day
Wind at 50 m6.7 m/s average
Water stress todayLow - Medium (10-20%) (Missouri)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Patmos KC2 use?

We estimate the facility power at about 106 MW. Estimate from building footprint, low confidence.

How close is Patmos KC2 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Crosstown Substation (161 kV), about 500 m away. The local utility is City Of Kansas City, in the SWPP balancing area.

How clean is the power for Patmos KC2?

The grid in Missouri emits about 674 g CO₂ per kWh (2025). Largest sources: coal 63.1%, gas 13%, nuclear 9.8%.

Who operates Patmos KC2?

Patmos Hosting.