Data Center Directory

ProRacks Datacenter- Kansas City

ProRacks Datacenter- Kansas City is an operational data center operated by ProRacks Datacenter Solutions in Kansas City, United States. No power figure is public for this site yet.

Key facts

StatusOperational
OperatorProRacks Datacenter Solutions
Address709 Forest Ave
Coordinates39.10485, -94.56800
Websiteproracks.com/kansas-city

Power and grid

Nearest high-voltage substationCharlotte Substation, 161 kV, 500 m away (Evergy)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationHawthorn Substation, 345 kV, 8.1 km away
HV substations within 10 km33
UtilityCity Of Kansas City (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authoritySWPP
Nearest gas pipelineSouthern Star Central Gas PL Co, interstate pipeline, 7.2 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km3.8 GW in 20 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity332 g CO₂ per kWh (Kansas, 2025)
Average of all power made in the area. Ember.
Grid power mixwind 46.9%, coal 30.6%, nuclear 14.7%, gas 6.5%, solar 1.1%. Clean power: 62.8%
Industrial power priceUSD 0.085 per kWh (Kansas, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature12.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature44.4 °C (2001 to 2025)
Cooling degree days784 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.23 kWh per m² per day
Wind at 50 m6.7 m/s average
Water stress todayHigh (40-80%) (Kansas)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How close is ProRacks Datacenter- Kansas City to the power grid?

The nearest high-voltage substation in OpenStreetMap is Charlotte Substation (161 kV), about 500 m away. The local utility is City Of Kansas City, in the SWPP balancing area.

How clean is the power for ProRacks Datacenter- Kansas City?

The grid in Kansas emits about 332 g CO₂ per kWh (2025). Largest sources: wind 46.9%, coal 30.6%, nuclear 14.7%.

Who operates ProRacks Datacenter- Kansas City?

ProRacks Datacenter Solutions.

Data centers near Kansas City

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.