Portus/IPHH HH3 (Wendenstrasse 251)
Portus/IPHH HH3 (Wendenstrasse 251) is an operational data center operated by Portus Data Centers in Hamburg, Germany. Our footprint estimate of its power is about 9.7 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Portus Data Centers |
| Facility power | 9.7 MW (range 4.9 MW to 16 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,623 m² building outline x 5 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 17 networks, 2 internet exchanges PeeringDB. |
| Also known as | GlobalConnect Hamburg (HAM3) |
| Address | Wendenstraße 251 |
| Coordinates | 53.55100, 10.03825 |
| Website | portusdatacenters.com/our-data-centers/hamburg |
Power and grid
| Nearest high-voltage substation | Umspannwerk St. Georg, 110 kV, 1.4 km away (Hamburger Energienetze) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Hamburg/Ost, 380 kV, 8 km away |
| HV substations within 10 km | 35 |
| Power plants within 50 km | 968 MW in 12 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.5 °C (2001 to 2025) |
| Cooling degree days | 70 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.88 kWh per m² per day |
| Wind at 50 m | 6.9 m/s average |
| Water stress today | Low (<10%) (Hamburg) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Portus/IPHH HH3 (Wendenstrasse 251) use?
We estimate the facility power at about 9.7 MW. Estimate from building footprint, low confidence.
How close is Portus/IPHH HH3 (Wendenstrasse 251) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk St. Georg (110 kV), about 1.4 km away.
How clean is the power for Portus/IPHH HH3 (Wendenstrasse 251)?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Portus/IPHH HH3 (Wendenstrasse 251)?
Portus Data Centers.
Data centers near Hamburg
- n@work Hamburg Grevenweg 423 m
- NorthC Hamburg 489 m · 6.8 MW
- n@work Hamburg Wendenstraße 582 m
- euNetworks Colocation Hamburg 671 m · 45 MW
- Artfiles w408 696 m
- ITENOS Hamburg (HAM1) 2.6 km
- Akquinet HAM01 6.8 km
- Akquinet HAM02 7.1 km
More Portus Data Centers data centers
- Portus LUX1 Luxembourg
- Portus MUC1 Germany