euNetworks Colocation Hamburg
euNetworks Colocation Hamburg is an operational data center operated by euNetworks in Hamburg, Germany. Our footprint estimate of its power is about 45 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | euNetworks |
| Facility power | 45 MW (range 23 MW to 72 MW) Estimate from building footprint, low confidence. Footprint estimate: about 9,376 m² building outline x 4 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 19,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 42 networks, 3 internet exchanges PeeringDB. |
| Also known as | Portus/IPHH HH2 (Wendenstrasse 408) |
| Address | Wendenstraße 408 |
| Coordinates | 53.54932, 10.04801 |
| Website | euNetworks.com |
Power and grid
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
|---|---|
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.5 °C (2001 to 2025) |
| Cooling degree days | 70 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.88 kWh per m² per day |
| Wind at 50 m | 6.9 m/s average |
| Water stress today | Low (<10%) (Hamburg) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does euNetworks Colocation Hamburg use?
We estimate the facility power at about 45 MW. Estimate from building footprint, low confidence.
How clean is the power for euNetworks Colocation Hamburg?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates euNetworks Colocation Hamburg?
euNetworks.
Data centers near Hamburg
- Artfiles w408 145 m
- n@work Hamburg Wendenstraße 188 m
- NorthC Hamburg 324 m · 6.8 MW
- n@work Hamburg Grevenweg 332 m
- Portus/IPHH HH3 (Wendenstrasse 251) 671 m · 9.7 MW
- ITENOS Hamburg (HAM1) 1.9 km
- Akquinet HAM01 7.1 km
- Akquinet HAM02 7.4 km
More euNetworks data centers
- euNetworks Amsterdam Netherlands
- euNetworks (Global Voice) Ireland
- euNetworks Colocation Karlsruhe Germany
- euNetworks Colocation Dortmund Germany
- euNetworks Colocation Bielefeld Germany
- euNetworks Colocation Bremen Germany
- euNetworks Colocation Dresden Germany
- euNetworks Colocation Erfurt Germany
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.