euNetworks Colocation Dortmund
euNetworks Colocation Dortmund is an operational data center operated by euNetworks in Dortmund, Germany. Our footprint estimate of its power is about 0.8 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | euNetworks |
| Facility power | 0.8 MW (range 0.4 MW to 1.2 MW) Estimate from building footprint, low confidence. Footprint estimate: about 639 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 340 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 6 networks, 1 internet exchanges PeeringDB. |
| Address | Im Spaehenfelde 51 |
| Coordinates | 51.52089, 7.48790 |
| Website | euNetworks.com |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 110 kV, 900 m away (Westnetz) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 220 kV, 1.8 km away |
| HV substations within 10 km | 26 |
| Power plants within 50 km | 8.2 GW in 51 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.2 °C (2001 to 2025) |
| Cooling degree days | 116 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.96 kWh per m² per day |
| Wind at 50 m | 6.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does euNetworks Colocation Dortmund use?
We estimate the facility power at about 0.8 MW. Estimate from building footprint, low confidence.
How close is euNetworks Colocation Dortmund to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (110 kV), about 900 m away.
How clean is the power for euNetworks Colocation Dortmund?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates euNetworks Colocation Dortmund?
euNetworks.
Data centers near Dortmund
- DOKOM21 RZ Hörde 3.4 km
- DOKOM21 RZ Huckarde 5.0 km · 2.7 MW
- Data center in Querenburg 16.5 km · 2 MW
- TMR Telehouse Bochum 18.9 km
- GFR DataCenter Herne 19.5 km
- GFR DataCenter Bochum 21.0 km
- Telemark Rechenzentrum Menden 21.4 km
- GELSEN-NET DC Resse 26.5 km
More euNetworks data centers
- euNetworks Colocation Hamburg Germany
- euNetworks Amsterdam Netherlands
- euNetworks (Global Voice) Ireland
- euNetworks Colocation Karlsruhe Germany
- euNetworks Colocation Bielefeld Germany
- euNetworks Colocation Bremen Germany
- euNetworks Colocation Dresden Germany
- euNetworks Colocation Erfurt Germany
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.